B-0 Class bulkhead certified by RINA with EC Type Examination Certificate No.MED471225CS/008 dated 11/04/2026 composed of two side by side bulkheads having maximum dimensions of 2440 (W) mm x 2500 (H) mm and thickness of 25 mm in which are installed two panels of a B-0 Class syde by side bulkhead certified by RINA with EC Type Examination Certificate No.MED108721CS/003 dated 12 April 2021 having maximum dimensions of 600 mm (W) x 2470 mm (H) and thickness of 16 mm; the two above mentioned panels may be fitted with the following accessories on each side:
- transit of electric cables having diameter of 9 mm composed of
N. 7 holes having diameter of 19 mm fitted with auto extinguishing plastic corrugated tube, having diameter of 16 mm, BOCCHIOTTI type FMP; the transit is fitted, on both the sides, with plastic ring type B-750-625 ELEKTROZUBEHOR;
N. 1 hole having diameter of 28 mm on the exposed side to the fire and diameter of 25.5 mm on the unexposed side to the fire fitted with auto extinguishing plastic corrugated tube, having diameter of 20 mm, BOCCHIOTTI type FMP and fitted, on the side exposed to the fire, with plastic ring type SB-1093-13 on the unexposed side to the fire, with plastic ring type B-1000-875 ELEKTROZUBEHOR.
- electric box composed of carbon steel sheet, 0.6 mm thick, and having dimensions of 185x80x34 mm fitted by steel clips and insulated, on the side not exposed to the fire, by means of one layer of material type KOBEMAT EGL having a density of 130 kg/m3, thickness of 12 mm and dimensions of 580x220 mm. The box may be fitted at a maximum height of 2100 mm.
- U shaped steel profiles, 2 mm thick and having dimensions of 80x10 mm fitted between the bulkhead steel sheets and the mineral wool and glued to the steel sheets on the side exposed to the fire.
Field of application
Fire resisting B-0 Class bulkhead for general application.
Reference documents
De Wave drawing No. DC-01-K1-44 dated 10 May 2019 approved on 12 April 2021 with endorsement No. LABS-2212.Tests carried out
Tests as per RINA Test Laboratory reports No. 2019CS011692/4 issued on 12 March 2020 according to IMO 2010 FTP Code. |