MED306326CSENGB- -  -  N- TK SEA03, TK SEA04,150 V- 250 V  -N- S- S- -24/07/2026- Marine Equipment- - SN- S- - N-  - 153,665B2bisMarine EquipmentNumero Pratica,Direttiva,Norma,Schema,Richiesta,Validità,EmailR- MED306326CS- N-Jul 24, 2031153665
 
Form
  Marine Equipment(TO)
MED306326CS
Certification N. MED306326CS - (ENG)
Certificate date 24/07/2026
Type Protezione antincendio
Product Fixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces: (i) Cables
Item Nº MED/3.51i

Model
Items/Sizes
TK SEA03, TK SEA04,150 V- 250 V  
Applicant TECNIKABEL S.P.A.
Place of requester VIA BRANDIZZO 243  %  10088 Volpiano (TO)  % ITALY
Tel. N.,Fax, Email +39 011 9951997, 011 9953062, CLERICI@TECNIKABEL.IT
Directive (EU) 2025/1533
Standard IEC 60092-376:2017,EN 60332-1-2:2004+A1:2015+A11:2016,IEC 60331-2:2018 (for fire resistant constructions only)
Reference Documents SOLAS 74 Reg. II-2/7,SOLAS 74 Reg. X/3,IMO Res. MSC.36(63)-(1994 HSC Code) 7,IMO Res. MSC.97(73)-(2000 HSC code) 7,IMO Res. MSC.98(73)-(FSS Code) 9,IMO Res. MSC391(95)-(IGF Code) 11,IMO MSC.1/Circ 1242,RINA Rules for the certification of Marine Equipment
Validity 24/07/2031
EC TYPE-EXAMINATION (MODULE B) ENG
Vuoto Querysave
Chiara Boscolo S

EC TYPE EXAMINATION (MODULE B)
CERTIFICATE No. MED306326CS

This is to certify that RINA Services S.p.A. (Notified Body No. 0474) did undertake the relevant type approval procedures for the equipment identified below, which was found to be in compliance with the Fire Protection requirements of Marine Equipment Directive (MED) 2014/90/EU, including the requirements and testing standards of Regulation (EU) 2025/1533.
MED Item Nº MED/3.51i
Description Fixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces: (i) Cables
Type TK SEA03, TK SEA04
Applicant TECNIKABEL S.P.A.
VIA BRANDIZZO 243,10088 Volpiano (TO),ITALY
Testing standards IEC 60092-376:2017,EN 60332-1-2:2004+A1:2015+A11:2016,IEC 60331-2:2018 (for fire resistant constructions only)
Reference standards SOLAS 74 Reg. II-2/7; SOLAS 74 Reg. X/3; IMO Res. MSC.36(63)-(1994 HSC Code) 7; IMO Res. MSC.97(73)-(2000 HSC code) 7; IMO Res. MSC.98(73)-(FSS Code) 9; IMO Res. MSC391(95)-(IGF Code) 11; IMO MSC.1/Circ 1242; RINA Rules for the certification of Marine Equipment
Issued in Genoa on
This Certificate is valid until
July 24, 2026
July 24, 2031
This Certificate consists of this sheet plus an attachment

________________________________________
Luigi Benedetti
RINA Services S.p.A.
**** NOTICE: This is NOT an official certificate ****

ATTACHMENT TO
CERTIFICATE No.  MED306326CS
Page 1 of 4
Materials/Components

Control and instrumentation cables, fire retardant, low smoke, halogen free, with optional fire resistant, shielding and armoured constructions, for ships and offshore units.


Characteristic
Description
Cable type
TK SEA03, TK SEA04
Rated Voltage
150/250 V
Maximum conductor temperature
90°C
Conductor
Bare/Tinned annealed Cu, IEC 60228 Cl.2, Cl.5 or Cl.6
Fire resistant barrier
Mica tape over conductor (TK SEA04 only)
Insulation
XLPE
Core assembly
Pairs/Triads with fillers if required
Individual shield (optional)
Al/PET tape + tinned Cu drain wire
Collective shield (optional)
Al/PET tape + tinned Cu drain wire
Inner sheat (optional)
SHF1
Armour (optional)
GSWB or plain/tinned Cu braid
Outer sheath
SHF1 or SHF2
Marking
TECNIKABEL (TO) - ITALY - (week/year) - Type - n° x section mm² - Rated Voltage - Applicable Standard



In accordance with IEC 60228; IEC 60092-350; IEC 60092-360; IEC 60092-376; IEC 60332-1-2; IEC 60332-3-22 Category A; IEC 60754-1; IEC 60754-2; IEC 61034-1; IEC 61034-2, RINA Rules for Ships; RINAMIL Rules; RINA Rules
for FSRU; RINAMIL for FREMM..

Additionally for TK SEA04: IEC 60331-2.

Type tested constructions include non-armoured SHF1 constructions, armoured SHF2 constructions, copper wire braid armoured constructions, galvanized steel wire braid armoured constructions, shielded constructions with individual and/or collective screens and fire resistant constructions incorporating mica tape.







ATTACHMENT TO
CERTIFICATE No. MED306326CS
Page 2 of 3

Technical Specifications:

TKSEA-03 Flame Retardant Rev.0 dated 18/06/2025;
TKSEA-03 Flame Retardant Armoured Rev.0 dated 18/06/2025;
TKSEA-04 Fire Resistant Rev.0 dated 18/06/2025;
TKSEA-04 Fire Resistant Armoured Rev.0 dated 18/06/2025;
ZZ62478-P Rev.2 dated 12/11/2024.
EMC performance ((in the marking "EMC"): transfer impedance: ≤ 25 mohm/m (0-100 MHz) acc. to IEC 62153-4-3
Drilling fluid resistance according to IEC 60092-360 Tab.9-10 with sheath SHF2 (in the marking "SHF2")





Type Test Reports:
Test Report No. 119 dated 09/06/2025;
Test Report No. 120 dated 09/06/2025.
Test Report N°92 rev.1 (23-26/03/2026)
Test Report N°85 rev.1 (23-26/03/2026)

Reference documents:
TAO-APP dated 25/07/2025
Offer 2026/16783accepted on 12/05/2026
The documents above-mentioned have been archived in the Leonardo Draw Plus portal under the project:
https://leodrawplus.rina.org/projects/82325/detail

















ATTACHMENT TO
CERTIFICATE No. MED306326CS
Pages 4 of 4
The mark of conformity may only be affixed to the above type approved equipment and a Manufacturer's Declaration of Conformity issued when the production control phase module (D, E or F) of Annex II of the Directive is fully complied with a written inspection agreement with a Notified Body
XXXX/YY
"WHEELMARK FORMAT"

XXXX
Notified Body number undertaking surveillance module
YY
Last two digits of year mark affixed
     
______________________________________________
General conditions for the approval
a) The initial conditions verified by RINA at the time of the approval are to be maintained
b) Any changes to the initial conditions are to be promptly communicated to RINA, which reserves the right to repeat the relevant assessment
c) This certificate will no be valid if the manufacturer makes any changes or modifications to the approved equipment, which have not been notified to, and agreed with RINA
d) RINA personnel are to be allowed to witness during the performances of activities, upon their request
e) The activities are to be carried out in compliance with the RINA Rules and/or other applicable Rules

f) Should the specified regulations or standards be amended during the validity of this certificate, the product is to be reapproved prior to it being placed on board vessels to which the amended regulations or standards apply. 


__________________________________________
Luigi Benedetti
**** NOTICE: This is NOT an official certificate ****