ELE340626XT!005ENG- -  -  N- FMGCG 60/250 V -N- S- S- -14/10/2026- Prodotti Elettrici- - SN- N- - N-  - 369,823BbisProdotti ElettriciNumero Pratica,NumDich,Norma,NumBusta,Richiesta,Validità- ELE340626XT/005- N-Oct 14, 2031369823
 
Form
  Prodotti Elettrici(TO)
Certification N. ELE340626XT/005 - (ENG)
Certificate date 14/10/2026
Type Impianti Elettrici
Product CAVI ELETTRICI

Model or Denomin.
Items
FMGCG 60/250 V
Applicant UNTEL KABLOLARI SANAYI VE TICARET A.S.
Place of requester MAKINE O.S.B. 6.CADDE, NO.4 DILOVASI  %  41455 KOCAELI  % TURKEY
Tel. N.,Fax, Email +90 262 722 9330, +90 262 722 9443, erdogan.malkoc@untel.com.tr
Standards DIN 89159,IEC 60092-375,IEC 60092-376.
Expire date 14/10/2031
Head Office ISTANBUL
Interrut.senza Dettaglio ENG
Vuoto Querysave
S
TYPE APPROVAL CERTIFICATE
No. ELE340626XT/005
This is to certify that the product below is found to be in compliance with the applicable requirement of the RINA type approval system.

Description ELECTRIC CABLES
Type FMGCG 60/250 V
Applicant UNTEL KABLOLARI SANAYI VE TICARET A.S.
Reference standards DIN 89159,IEC 60092-375,IEC 60092-376.
  

 
 
   .   This Certificate is valid until October 14, 2031
_________________________________
RINA Services S.p.A.
Oytun Uzun
This certificate consists of this page and 1 enclosure
**** NOTICE: This is NOT an official certificate ****

TYPE APPROVAL CERTIFICATE
No. ELE340626XT/005
Enclosure - Page 1 of 1
FMGCG 60/250 V
Materials/Components

Shipboard power cables, flame retardant, for ships and off-shore units installation.

Rated voltage: 60 - 250 V

Type: FMGCG

Marking: UNTEL DIN 89159 IEC 60092-376 FMGCG n x s mm2 IEC 60332/3A 250 V


Construction:
conductor: stranded tinned copper wire class 2 or 5, tinned on request

insulation: HEPR
laid up: cores laid up in pairs
separating foil: over cable core, foil
screen: tinned or plain copper braid wires
separating foil: above braided screen, foil
sheath: CR (SE1)

Max. conductor temperature: 85°C.

In accordance to rules DIN 89159; IEC 60228 ; IEC 60092-350; IEC 60092-376; IEC 60092-360; IEC 60332-1-2; IEC 60332-3-22.


Conductor size:

number of cores X pairs 1,2,4,7,10,14,19,24 - cross-sectional area 0.5, 0.75, 1, 1.5 mm2

Technical specification: data sheet N. FR 70-062 Rev1 dated 01/07/2011.


ISTANBUL 14/10/2026
**** NOTICE: This is NOT an official certificate ****