Materials/Components
Shipboard power cables, flame retardant, for ships and off-shore units installation.
Rated voltage: 60 - 250 V
Type: FMGCG
Marking: UNTEL DIN 89159 IEC 60092-376 FMGCG n x s mm2 IEC 60332/3A 250 V
Construction:
conductor: stranded tinned copper wire class 2 or 5, tinned on request
insulation: HEPR
laid up: cores laid up in pairs
separating foil: over cable core, foil
screen: tinned or plain copper braid wires
separating foil: above braided screen, foil
sheath: CR (SE1)
Max. conductor temperature: 85°C.
In accordance to rules DIN 89159; IEC 60228 ; IEC 60092-350; IEC 60092-376; IEC 60092-360; IEC 60332-1-2; IEC 60332-3-22.
Conductor size:
number of cores X pairs 1,2,4,7,10,14,19,24 - cross-sectional area 0.5, 0.75, 1, 1.5 mm2
Technical specification: data sheet N. FR 70-062 Rev1 dated 01/07/2011.