1. Product Description
0.6/1kV shipboard electric power cables with following rating:
Type
Designation | Rated
Volt.
[KV] | Number of
Cores | Nominal Conductor
Cross-sectional
Area [mm²] | Maximum rated
Conductor
Temperature [℃] | Fire Property |
CJV, CJV80|90|82|92, CJVR, CJ82|92
(/SA/NA)
CJPF, CJPF80|90|86|96, CJPFR, CJ86|96
CJPJ, CJPJ80|90|85|95, CJPJR, CJ85|95
(/SC/NC/NSC) | 0.6/1 | 1
2
3 (2+E)
4 (3+E)
5 ~ 37 | 1.0 ~ 300
1.0 ~ 120
1.0 ~ 185
1.0 ~ 150
1.0 ~ 2.5 | 90 | Flame-retardant
- IEC 60332-1
- IEC 60332-3-22
Fire-resistant
- IEC 60331-1
- IEC 60331-2 |
CEV, CEV80|90|82|92, CEVR
CEF, CEF80|90|82|92, CEFR
(/SA/NA)
CEPF, CEPF80|90|86|96, CEPFR
CEPJ, CEPJ80|90|85|95, CEPJR
(/SC/NC/NSC) |
Note: +“Conductor Cross-section” is selected from the following series of conductor size:
1.0, 1.5, 2.5, 4, 6, 10, 16, 25, 35, 50, 70, 95, 120, 150, 185, 240, 300 mm2
+“Number of Core” is selected from the following series of core number:
1, 2, 3, 4, 5, 7, 10, 12, 14, 16, 19, 24, 27, 30, 33, 37
+Conductor: Stranded bare or tinned annealed copper - Class 2 or 5
+Insulation: Cross-linked polyethylene -XLPE(J)
Ethylene Propylene Rubber - EPR (E)
+Inner Sheath: (Option):
Thermoset compound – SE1 (F)
Thermoplastic compound - ST2 (V)
Halogen Free Thermoplastic compound - SHF1 (PF)
Halogen Free Thermoset compound - SHF2 (PJ)
+Armor:
8: Copper wire braided
9: Steel wire braided
+Outer Sheath:
0: None
2: Thermoplastic Compound - ST2
5: Halogen Free Thermoset Compound - SHF2
6: Halogen Free Thermoplastic Compound - SHF1
Enclosure - Page 2 of 2
CJ Series, CJV Series, CJPF Series, CJPJ Series
CEV Series, CEF Series, CEPF Series, CEPJ Series
+Other properties’ suffix:
C: Shipboard power cable
R: Flexible cable
+Flammability Code:
SA: Bunched flame retardant cable, comply with IEC 60332-3, IEC 60332-1.
NA: Fire resistant cable, comply with IEC60332-3, IEC 60332-1, IEC60331
SC: Halogen-free Low-smoke bunched flame retardant cable, comply with IEC 60332-3,IEC 60332-1, IEC60754, IEC61034
NC: Halogen-free Low-smoke bunched flame retardant fire resistant cable, comply with IEC 60332-3, IEC 60332-1, IEC60331, IEC 60754, IEC61034
NSC: Halogen-free Low-smoke bunched flame fire resistant cable, comply with IEC 60332-3, IEC 60332-1,IEC60331, IEC 60754, IEC 61034.
2. Reference Documents:
+ Specification of marine power cables. Filed by RINA with drawing No.SHEL-11300.
+ Test Report: “Shanghai Intelligent Service and Technology Co., Ltd” Report No.: TN20-4804E, TN20-4805E, TN20-4806E, TN20-4807E, TN20-4810E, TN21-0727E, TN21-0728E, TN21-0729E. Filed by RINA with drawing No. SHEL-11303 and SHEL-11304.
+ Routine test Report signed by RINA Surveyor. Filed by RINA with drawing No.SHEL-11302.
+ Asbestos-free Declaration: Filed by RINA with drawing No. SHEL-11299.
3. Notes/Remarks:
+ The product is subject to the compliance with RINA Rules and Standards mentioned on the certificates.
+ Type Approval certifies that a representative sample of the product has been found to meet the applicable design criteria.
+ Any modification or change shall not be valid until approval is granted by RINA as a result of due assessment. |
|