| Double asimetric leaf hinged door with maximum clear light of 1200x2100 mm (WxH). The primary leaf, having maximum dimensions of 913x2110 mm (WxH) and the secondary leaf, having maximum dimensions of 313x2110 mm (WxH) are composed of two steel sheets, 1.2 mm thick each, and, in between, the insulating material composed of a layer of material named PROMASIL MARINE, 35 mm thick and having density of 285 kg/m3. The insulating material is glued to the steel sheets by means of 200 g/ m2 of adhesive type PROTOPUR AE 100. The door frame is composed of an hollow steel profile, 1.2 mm thick and having dimensions of 40x48.7 mm; the frame, on the upper side has dimensions of 125x48.7 mm and is filled with mineral wool (certified non combustible in conformity to the requirements of the IMO FTP Code) having density of 150 kg/m3. The primary leaf may be fitted with a rectangular window having maximum clear light of 300x400 mm (WxH); the glass compound, type PYROBELYTE 12 (manufacturer Glaverbel) and having total thickness of 12 mm, is composed of 3 panes and, in between, 2 layers of thermo-expanding gel. The window frame is composed of stainless steel profiles having thickness of 1.2 mm fixed to the leaf with 4mm rivets fitted with pitch of 100 mm; between glass and frame are fitted gaskets type PAPERSEAL ECO (thickness of 3 mm). Field of application Fire resistant B-15 Class double leaf hinged door. The door is also in compliance with IMO MSC.1/Circ. 1319 dated 11 June 2009. In this case the dimensions relevant to the height and width of the door may be increased of 15% provided that the surface area is not increased of more than 10%.
In case of doors in compliance to the "Agreement between the EEA EFTA States and the United States of America", the present certificate is valid at the following conditions:
- doors without windows or with total window area no more than 645 cm2 in each door leaf
- maximum door size tested
- door used with a fire tested frame designReference documents SIN SERVICE drawing No. B15PRO2AA dated 12 October 2018 approved on 3 December 2018 with endorsement No. LABS-1780.Tests carried out Test as per RINA Test Laboratory report No. 2018CS013455/1 issued on 18 December 2018 according to Appendix 1 of IMO 2010 FTPC Part 3.
This certificate annuls and replaces the certificate No. MED345518CS/001 dated 14 January 2019 due to mention of the additional requirements indicated on the "Agreement between the EEA EFTA States and the United States of America" |