Non-metallic expantion joints, type COFLEX DCF1 manufactured by "ISOPREN s.r.l."
- Inner side: aging resistant synthetic rubber,
- Reinforcement: textile braids covered with rubber,
- Insert: steel,
- Cover: aging resistant synthetic rubber,
- Couplings: flange (from ND25 to ND250) and AGR-K fittings (from ND25 to ND40) made of carbon and stainless steel
provided with a flame-proof guard ( COFLEX CF1 ) composed by :
- internal layer "2002 AL HT" aluminized glass fabric
- heat insulation layer composed by:
- soft temper aluminium foil, nominal thickness 0.050 mm
- "SUPERWOOL 607" glass fiber for high temperature (1100 °C) having nominal thickness 13 mm and density 128 Kg/m3
- "FILOMAT AS 800" not flammable glass fiber having nominal thickness 6 mm and density 130 Kg/m3
- external layer "2002 AL HT" aluminized glass fabric
A plate, showing the instruction according to technical specifications, will be fitted on the guard external surface. REFERENCE DOCUMENTS
COFI drawings no. 040546 rev. 2 Tables 1/2 and 2/2, approved by RINA with nos. PPVT-12001 and PPVT-12002.
COFI drawing no. 040553 rev. 2, approved by RINA with no. PPVT-12003.
COFI technical specification no. 110069 rev. 1 dated January 2011, filed by RINA with no. PPVT-11955.
COFI technical instruction no. 0029 rev. 7 dated January 2011, filed by RINA with no. PPVT-11956.
COFI drawings no. 040631 rev. 3 approved by RINA with nos. PPVT-26700 to PPVT-26703.
TECHNICAL DATA
Nominal Diameter 25 to 250 (mm)
Maximum working pressure Pe 1,6 (MPa)
Working temperature: - 10 °C to +90 °C (according to information on the approved drawings)
ATTACHMENT TO
No. MED165722CS
page 2 of 3
TEST CARRIED OUT
Fire resistance tests carried out by RINA Fire Protection Research Laboratory on 01-02/02/2011 as per test reports Nos. 2011CS01173/6, 2011CS01173/7, 2011CS01173/8, 2011CS01173/9 and on 29/05/2017 as per test reports Nos. 2017CS01639 and 2017CS01639/1
REMARKS
Flanges are to be in accordance with a recognized standard.
This certificate annuls and replaces the certificate No. MED093717CS dated 09/20/2017 due to renewal, without any modification in the equipment, as per Manufacturer's request.
This certificate also annuls and replaces the certificate No. MED165722CS dated 05/13/2022 due to misprinting in the certificate.