MED325622XG!001ENG- -  -  N- "MDM EZ Path® Marine Cable Transit" -N- S- S- -06/02/2023- Marine Equipment- - SN- S- - N-  - 1,050,770B2bisMarine EquipmentNumero Pratica,Direttiva,Norma,Schema,Richiesta,Validità- MED325622XG/001- N-Feb 6, 20281050770
 
Form
  Marine Equipment(TO)
Certification N. MED325622XG/001 - (ENG)
Certificate date 06/02/2023
Type Protezione antincendio
Product Penetrations through "A" Class divisions: (a) electric cable transits
Item Nº MED/3.26a
USCG Category N° 164.138

Model or Denomin.
Items
"MDM EZ Path® Marine Cable Transit"
Applicant STI Marine Firestop, a division of Specified Technologies Inc.
Place of requester 210 Evans Way  %  08876 Somerville (New Jersey)  % U.S.A.
Tel. N.,Fax, Email +19085268000, ---, jlopes@stimarine.com
Directive (EU) 2022/1157
Standards IMO Res. MSC.307(88)-(2010 FTP Code) - IMO MSC.1/Circ. 1488
Reference Documents Chap. II-2 of SOLAS 74 Convention, as amended, RINA Rules for the certification of Marine Equipment
Request 18/12/2017
Expire date 06/02/2028
Head Office Hamburg
EC TYPE-EXAMINATION (MODULE B) ENG
Vuoto Querysave
Giuseppe Russo S

EC TYPE EXAMINATION (MODULE B)
CERTIFICATE No. MED325622XG/001

This is to certify that RINA Services S.p.A. (Notified Body No. 0474) did undertake the relevant type approval procedures for the equipment identified below, which was found to be in compliance with the Fire Protection requirements of Marine Equipment Directive (MED) 2014/90/EU, including the requirements and testing standards of Regulation (EU) 2022/1157.
MED Item Nº MED/3.26a
USCG Category Nº 164.138
Description Penetrations through "A" Class divisions: (a) electric cable transits
Type "MDM EZ Path® Marine Cable Transit"
Applicant STI Marine Firestop, a division of Specified Technologies Inc.
210 Evans Way,08876 Somerville (New Jersey),U.S.A.
Testing standards IMO Res. MSC.307(88)-(2010 FTP Code) - IMO MSC.1/Circ. 1488
Reference standards Chap. II-2 of SOLAS 74 Convention, as amended, RINA Rules for the certification of Marine Equipment
Issued in Hamburg on
This Certificate is valid until
February 6, 2023
February 6, 2028
This Certificate consists of this sheet plus an attachment

________________________________________
Giuseppe Russo
RINA Services S.p.A.
**** NOTICE: This is NOT an official certificate ****

ATTACHMENT TO
CERTIFICATE No.  MED325622XG/001
Page 1 of 5

Product Description


EZ Path Marine Cable Transits consist of heavy gauge, galvanized steel shells containing
self-adjusting intumescent liners. The shell dimensions for the MDM150, MDM300 and
MDM400 transits are as follows:

MDM150: 150mm wide x 75mm high x 150mm long (6” x 3” x 6”)

MDM300: 75mm wide x 75mm high x 267mm long (3” x 3” x 10-1/2”)

MDM400: 102mm wide x 118mm high x 356mm long (4” x 4-5/8” x 14”)

Steel mounting plates are secured around the shells to facilitate attachment to the division.
Mounting plate designs allow modular units to be installed individually or in ganged
configurations with multiple units per opening.

Installations as per manufacturer instruction.

Field of Application

The transits are intended for single and multi-cable penetrations through A-0 – A-60 Class,
non-watertight steel or aluminum bulkheads or decks and A-0 – A-60 Class panel bulkheads.

The transits can accommodate 0 – 100% visual cable fill.

The transits are to be installed and insulated (in addition to the approved insulation arrangements
for the division) as detailed in the following tables:








Attachment to Certificate No. MED325622XG/001 Page 2 of 5


Notes:
MDM400K/L/M may be installed with opening dimensions listed for MDM400A/C/G, respectively.
MDM400N may be installed in 315mm x 126mm opening with 6mm radius at corners.



Attachment to Certificate No. MED325622XG/001 Page 3 of 5



Notes:
MDM400K/L/M may be installed with opening dimensions listed for MDM400A/C/G, respectively.
MDM400N may be installed in 315mm x 126mm opening with 6mm radius at corners.










Attachment to Certificate No. MED325622XG/001 Page 4 of 5

Reference Documents and Tests Carried Out

STI Drawing No. STIM0152 (RINA Doc. No. HMFP/8682), dated 01/26/23 – MDM150,
A-0 – A-60 steel or aluminum bulkhead or deck.
STI Drawing No. STIM0153 (RINA Doc. No. HMFP/8736), dated 07/28/22 – MDM300,
A-0 – A-60 steel bulkhead or deck.
STI Drawing No. STIM0154 (RINA Doc. No. HMFP/8681), dated 01/26/23 – MDM400,
A-0 – A-60 steel bulkhead or deck and A-0 – A-60 panel bulkhead.
STI Drawing No. STIM0178 (RINA Doc. No. HMFP/8737), dated 10/24/22 – MDM400,
A-0 – A-60 steel bulkhead .


Testing References filed with RINA Doc. No. HMFP/8735.

Test Reports filed with RINA Doc. No. HMFP/6608, HMFP/8727-8734.

Reference is to be done also to technical drawings, test reports and data filed with letter RINA
letter HMFP/2017/00025/LCAIV.
Remarks

1. All penetrations are to be insulated to same fire class as bulkhead and deck. Other applications
are subject to case-by-case approval. The insulation materials are to be approved.

2. In A-0, A-15 and A-30 divisions, where the configuration is not described in the tables, the
transit is to be insulated per the A-60 design on the penetration itself and for 200mm around.

3. Production items are to be manufactured in accordance with a quality control system which
shall be maintained to ensure that items are of the same standard as the approved prototype.

4. These types of penetrations are not suitable for tank boundaries and where the penetrations
are subject to frequent immersion in fluids. Such scope is to be considered on case-by-case basis.

5. The validity of this Certificate ceases in the case of amendments to the rules on the basis of
which the Certificate was issued.




ATTACHMENT TO
CERTIFICATE No. MED325622XG/001
Pages 5 of 5

Acceptance conditions:

This Application is not suitable on divisions where watertightness properties are requested.
· The validity of the present certificate is based on the assumption of the constant conformity of the single product manufactured to the prototype that has been tested with positive results to the type approval tests. The firm is responsible in the whole of the above mentioned conformity.
· The holder of the type approval certificate has to inform RINA of any intended modifications to the product and/or manufacturing process which are liable to effect the required conformity of the product.
· The certificate becomes automatically invalid in the following case:
1. the holder of the certificate does not respect the above mentioned obligations.
2. changes have been made to the reference document on which the type approval is based.
· The type approval certificate may be declared suspended or cancelled by RINA when the conditions on which the type approval was based are not fulfilled:
The mark of conformity may only be affixed to the above type approved equipment and a Manufacturer's Declaration of Conformity issued when the production control phase module (D, E or F) of Annex II of the Directive is fully complied with a written inspection agreement with a Notified Body
XXXX/YY
"WHEELMARK FORMAT"

XXXX
Notified Body number undertaking surveillance module
YY
Last two digits of year mark affixed
     
______________________________________________
General conditions for the approval
a) The initial conditions verified by RINA at the time of the approval are to be maintained
b) Any changes to the initial conditions are to be promptly communicated to RINA, which reserves the right to repeat the relevant assessment
c) This certificate will no be valid if the manufacturer makes any changes or modifications to the approved equipment, which have not been notified to, and agreed with RINA
d) RINA personnel are to be allowed to witness during the performances of activities, upon their request
e) The activities are to be carried out in compliance with the RINA Rules and/or other applicable Rules

f) Should the specified regulations or standards be amended during the validity of this certificate, the product is to be reapproved prior to it being placed on board vessels to which the amended regulations or standards apply. 


__________________________________________
Giuseppe Russo
**** NOTICE: This is NOT an official certificate ****