MED343625CS!002ENGF- -  -  N- Class A-0 Fast Open and close Watertight Fireproof Steel Door -N- S- S- -29/06/2025- Marine Equipment- - SN- S- - N-  - 2,335,224B2bisMarine EquipmentNumero Pratica,Direttiva,Norma,Schema,Richiesta,Validità,EmailR- MED343625CS/002- N-Jun 28, 20302335224
 
Form
  Marine Equipment(TO)
Certification N. MED343625CS/002 - (ENG)
Certificate date 29/06/2025
Type Protezione antincendio
Product Porte tagliafuoco
Item Nº MED/3.16
USCG Category N° 164.136

Model or Denomin.
Items
Class A-0 Fast Open and close Watertight Fireproof Steel Door
Applicant NANJING LISHUI YISHENG SHIP FITTINGS FACTORY
Place of requester ROOM 321,322,323, TECHNOLOGY ENTREPRENEURSHIP SERVICE CENTER, 688 TIANSHENGQIAO AVENUE, YONGYANG TOW Nanjing (Jiangsu)  % CHINA
Tel. N.,Fax, Email 025-57483908, ---, ct13851972698@163.com
Directive (EU) 2024/1975
Standards IMO Res. MSC.307(88)-(2010 FTP  Code), as amended.
Reference Documents SOLAS 74 Reg.II-2/9, IMO MSC.1/Circ.1511
Request 21/05/2025
Expire date 28/06/2030
EC TYPE-EXAMINATION (MODULE B) ENG
Vuoto Querysave
Enrico Cabella S

EC TYPE EXAMINATION (MODULE B)
CERTIFICATE No. MED343625CS/002

This is to certify that RINA Services S.p.A. (Notified Body No. 0474) did undertake the relevant type approval procedures for the equipment identified below, which was found to be in compliance with the Fire Protection requirements of Marine Equipment Directive (MED) 2014/90/EU, including the requirements and testing standards of Regulation (EU) 2024/1975.
MED Item Nº MED/3.16
USCG Category Nº 164.136
Description Fire doors
Type Class A-0 Fast Open and close Watertight Fireproof Steel Door
Applicant NANJING LISHUI YISHENG SHIP FITTINGS FACTORY
ROOM 321,322,323, TECHNOLOGY ENTREPRENEURSHIP SERVICE CENTER, 688 TIANSHENGQIAO AVENUE, YONGYANG TOW Nanjing (Jiangsu),CHINA
Testing standards IMO Res. MSC.307(88)-(2010 FTP  Code), as amended.
Reference standards SOLAS 74 Reg.II-2/9, IMO MSC.1/Circ.1511
Issued in Genoa on
This Certificate is valid until
June 29, 2025
June 28, 2030
This Certificate consists of this sheet plus an attachment

________________________________________
Enrico Cabella
RINA Services S.p.A.
**** NOTICE: This is NOT an official certificate ****

ATTACHMENT TO
CERTIFICATE No.  MED343625CS/002
Page 1 of 2

Product description

Single leaf hinged door whose maximum clear opening size is 1000 mm wide and 2100 mm high. The door leaf, having maximum width of 1064 mm, height of 2164 mm and thickness of 61 mm, is composed moving from the exposed side, of a carbon steel plate 3 mm thick, one layer of ceramic fiber and a carbon steel plate 8 mm thick having the edges bended to the rabbet; between the two steel plates are provided stiffeners, welded to the 8 mm thick steel plate, composed by four horizontal “L” steel profiles 50x50x6 mm and one vertical steel plate 50x9 mm. The 3 mm thick steel plate is fixed with 26 screws M6x12mm. Inside the leaf is fitted an insulating material composed by a layer of ceramic fiber (certified not combustible in conformity to the requirements of the IMO FTP Code), 20 mm thick having density of 170 kg/m3. The door frame, welded to the unexposed side of the bulkhead, is composed by a carbon steel “L” profile having dimensions of 100x75x10 mm and a carbon steel “L” profile 38x38x5 mm on which, in the inner side, are provided fireproof sealing strips 20x4 mm type 8935 provided by Shanghai Jiar Fu Decoration Material Company Ltd; on the lateral side are installed three steel hinges. The door is equipped with a lever closing device that acts on six points, fitted on the side exposed to the fire and actuated by a handle. The closure is made tight with neoprene gaskets, provided by Haida-MacGregor Jiangyin Sealing Co., Ltd, having dimensions of 40x20 mm fitted along the perimeter between the frame and the leaf rabbet. The leaf may be fitted with rectangular window having maximum clear size of 300x400 mm having radiused corners with radius of 100 mm. The pane, type Cesium Potassium monolitich glass, having thickness of 12 mm provided by Yixing Yushi Special Glass Co., Ltd, is held in place by means of two symmetrical steel frame S shaped profiles having thickness of 5 mm, dimensions 25x15x13mm, bolted by N.14 M6x65 bolts, fitted with pitch of 85 mm. Between the glass and the frame is provided a 2 mm thick neoprene gasket.
Field of application
Fire resistant A-0 Class single leaf hinged door.
In case of doors in compliance to the "Agreement between the European Community and the United States of America", the present certificate is valid at the following conditions:
- doors without windows or with total window area no more than 645 cm2 in each door leaf
- maximum door size tested
- door used with a fire tested frame design
Reference documents
Nanjing Lishui Yisheng Ship Fitting Factory drawing No. 124YS01-20-00 attached to the Far East Fire Testing Centre (FEFTC) Test Report No. FT12288 issued on 23 November 2012.
Tests carried out
Tests as per Far East Fire Testing Centre (FEFTC) Test Report No. FT12288 issued on 23 November 2012 according to 2010 FTP Code Annex 1, Part 3.




ATTACHMENT TO
CERTIFICATE No. MED343625CS/002
Pages 2 of 2
The mark of conformity may only be affixed to the above type approved equipment and a Manufacturer's Declaration of Conformity issued when the production control phase module (D, E or F) of Annex II of the Directive is fully complied with a written inspection agreement with a Notified Body
XXXX/YY
"WHEELMARK FORMAT"

XXXX
Notified Body number undertaking surveillance module
YY
Last two digits of year mark affixed
     
______________________________________________
General conditions for the approval
a) The initial conditions verified by RINA at the time of the approval are to be maintained
b) Any changes to the initial conditions are to be promptly communicated to RINA, which reserves the right to repeat the relevant assessment
c) This certificate will no be valid if the manufacturer makes any changes or modifications to the approved equipment, which have not been notified to, and agreed with RINA
d) RINA personnel are to be allowed to witness during the performances of activities, upon their request
e) The activities are to be carried out in compliance with the RINA Rules and/or other applicable Rules

f) Should the specified regulations or standards be amended during the validity of this certificate, the product is to be reapproved prior to it being placed on board vessels to which the amended regulations or standards apply. 


__________________________________________
Enrico Cabella
**** NOTICE: This is NOT an official certificate ****