ATTACHMENT TO
|
CERTIFICATE No. MED296521WS/001
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Verified components of the equipment (with serial
number) |
|
|
|
S/N.: 100SC1 & 100SC2, Intended for: M/V FINNECO I (IMO 9856830, RI 97927) |
|
|
|
|
|
|
|
| Technical documentation |
|
|
|
1. Following statutory document have been approved/filed in compliance with IMO Res. MEPC.176(58) - (Revised MARPOL Annex VI, Reg.4) and IMO Res. MEPC.259(68): 1.1 Onboard Monitoring Manual (OMM), PLMC/4216, 1.2 Technical Manual, Scheme B (ETM-B), PLMC/1526, 1.3 SOx Emission Compliance Plan, Scheme B (SECP), PLMC/1528, 1.4 EGC Record Book, PLMC/4098.
2. Product description: The EGCS installed onboard the vessel consists of two (2) scrubber towers for cleaning the exhaust gas from two main engines respectively. Exhaust gas emissions of the main engines can be cleaned by the EGCS equivalent to using fuel oil with Sulphur content upper limit value of 0.1% m/m. This emission compliance is monitored continuously by measuring and recording of SO2(ppm)/CO2 (%) ratio and other key parameters as specified in the Technical Manual ETM-B with approval No. PLMC/1526.
3. Completed Tests on board were carried out and witnessed by RINA surveyor on 06/10/2021 in accordance with IMO Res. MEPC.259(68) & approved documents, and relevant testing reports/ records are listed as below: 3.1 Commissioning test report. 3.2 EGC history data recording report during sea trial tests. 3.3 Bunker Delivery Notes. 3.4 FAT report for automation system. 3.5 Calibration protocols/certificates of CEMS and water monitoring sensors. 3.6 Span gas certificates. 3.7 RINA testing certificate for main components. 3.8 Wash water sample analyses report issued by recognized laboratory.
4.This certificate replaces previous module G certificate No.: MED296521WS
|
Limitation on the acceptance or use of the
product
The maximum exhaust mass flow rate is 94,320 kg/h for each EGC unit, and the maximum Sulphur content of fuel oil is 2.8%. For other operating limits, technical manual ETM (PLMC/1526) is to be referred.
____________________________ |
|
|
General condition of approval
a) This certificate will not be valid if the manufacturer or user makes any modification to the equipment, which has not been notified to, and agreed with RINA |
|
|
|