ASL level switch, single (S) and double (D) version
Main features:
Ultrasonic ON-OFF level switch with piezoceramic sensor
Materials: Housing, Process connection, flange, antenna rods, cable gland : AISI 316 / Titanium / Hastelloy
Antenna length: 900 mm Max ; D = 22 / 28 mm
Power supply: 24Vdc + 30%Vn / -25%Vn
Outputs: ON - OFF 5 / 13 mA; free voltage contacts
Mechanical protection: IP 67 (EN60529) ; IP 68 @1,5m
EU- TYPE EXAMINATION CERTIFICATE
Equipment or Protective System Intended for use in potentially explosive atmospheres
Safety marking:
Certification Authority: TECHNICKA INSPEKCIA a.s. -Slovakia (NB 1354)
ATEX Certificate: TI17ATEX 310 X (March 14th 2017)
Marking:
For Stainless Steel housing with IP 68 (Code A1)
II 1 GD Ex ia IIC T6 Ga -40°C ≤ Tamb + 40°C and Ex ia IIIC T85°C Da
II 1 GD Ex ia IIC T6 Ga -40°C ≤ Tamb + 55°C and Ex ia IIIC T100°C Da
For Stainless Steel housing with IP 66 (Code A2)
II 1 G Ex ia IIC T6 Ga -40°C ≤ Tamb + 40°C
II 1 G Ex ia IIC T6 Ga -40°C ≤ Tamb + 55°C
Safety Requirements: EN60079-0:2012+A11:2013, EN60079-11:2012
Admissible Electrical parameters value
| Paramete | Value |
| Maximum Voltage Ui | 30 V |
| Maximum Current Ii | 100 mA |
| Maximum Power Pi | 0,75 W |
| Maximum Capacitance Ci | 10 nF |
| Maximum Inductance Li | 0,1 mH |
Nemko Test reports:
doc. 274763-TRFEMC, (2015/01/09) - Emissions - Immunity EMC;
doc. 274763-2TREnvEx , (2015/02/20) - Climatic ; doc. 275088-1TRFEnvEx , (2015/04/14) -Vibrations
doc. 274763-1TREnvEx, (2015-02-16) - Salt mist; doc. 274763-1TRSAF, (2015-02-20) - Insulation
doc. 275088-2TRFEnvEx , (2015-02-25) - IP test;
doc. REP100868 , (2025-06-16) - IP test;
doc. IND 1749-1A/03 (2003/09/22) IP test , doc. IND 1749-1B/03, (2003/09/22) IP test
Valcom Test report:
doc. n. DTL201502 rev. 0 2015/04/16, Power supply variations:
Valcom Specification:
Data sheet : Ultrasonic Level Switch Series ASL _ doc. n. DSASL Rev. 17.01
ASL RINA GAP ANALYSIS 2025
General remark:
Condition of use in potentially explosive atmosphere to be in accordance with the requirements described in the relevant safety
certificates in force
|
|