| S101 RFOU(i)/TFOU(i) /E/M, S102 RFOU(c)/TFOU(c) /E/M,S103 BFOU(i) /E/M, S104 BFOU(c) /E/M, RFOU(i&c)/TFOU(i&c) /E/M, BFOU(i&c) /E/M,RFCU(i)/TFCU(i) /E/M, RFCU(c)/TFCU(c) /E/M,BFCU(i) /E/M,BFCU(c) /E/M, RFCU(i&c)/TFCU(i&c) /E/M,BFCU(i&c) /E/M, S105 RU(i)/TU(i) /E/M, S106 RU(c)/TU(c) /E/M, S107 BU(i) /E/M, S108 BU(c) /E/M, RU(i&c)/TU(i&c) /E/M, BU(i&c) /E/M, S109 BFOU-HCF(i) /E/M, S110 BFOU-HCF(c) /E/M, BFOU-HCF(i&c) /E/M, BFCU-HCF(i) /E/M, BFCU-HCF(c) /E/M, BFCU-HCF(i&c) /E/M |
1. Production Description:
Shipboard Instrument Cable with Following Rating:
Type | Rated Voltage (V) | Number of Core | Conductor Cross-section
(mm2) | Max. Temp. (℃) |
S101 RFOU(i)/TFOU(i) /E/M,
S102 RFOU(c)/TFOU(c) /E/M,
S103 BFOU(i) /E/M,
S104 BFOU(c) /E/M,
RFOU(i&c)/TFOU(i&c) /E/M,
BFOU(i&c) /E/M
RFCU(i)/TFCU(i) /E/M,
RFCU(c)/TFCU(c) /E/M,
BFCU(i) /E/M,
BFCU(c) /E/M,
RFCU(i&c)/TFCU(i&c) /E/M,
BFCU(i&c) /E/M
S105 RU(i)/TU(i) /E/M,
S106 RU(c)/TU(c) /E/M,
S107 BU(i) /E/M,
S108 BU(c) /E/M,
RU(i&c)/TU(i&c) /E/M,
BU(i&c) /E/M
S109 BFOU-HCF(i) /E/M,
S110 BFOU-HCF(c) /E/M,
BFOU-HCF(i&c) /E/M
BFCU-HCF(i) /E/M,
BFCU-HCF(c) /E/M,
BFCU-HCF(i&c) /E/M | 150/250
| 1P-48P
1T-48T | 0.5, 0.75, 1.0, 1.5, 2.5, 4, 6 | 90 |
600/1000 |
Note:
+ “Number of core” is selected from the following series of core number:
1P, 2P, 3P, 4P, 5P, 6P, 7P, 8P, 10P, 12P, 14P, 15P, 16P,19P, 20P ,24P, 27P, 30P, 33P, 37P,44P, 48P
1T, 2T, 3T, 4T, 5T, 6T, 7T, 8T, 10T, 12T, 14T, 15T, 16T,19T, 20T ,24T, 27T, 30T, 33T, 37T,44T, 48T
TYPE APPROVAL CERTIFICATE
NO, ELE539925WS/005
Enclosure - Page 2 of 2
+Meaning of The Code
R | EPR Insulation |
T | XLPE Insulation |
B | Fire -Resistant Cable |
F | Low-smoke, halogen-free polymer Inner Covering |
O | Tinned Copper Wire Braiding Armour |
C | Galvanized Steel Wire Braiding Armour |
U | SHF2 Category a Sheath |
E | SHF2 Category b Sheath |
M | SHF2 Category c Sheath |
(i) | Individual Screen |
(c) | Overall Screen |
(i&c) | Individual Screen and Overall Screen |
-HCF | HC(1100 C/Degree, the minimum fire resistance time is 30 minutes ) Fire -Resistant Power Cable |
2. Reference Documents:
+ Specification of marine cables. Filed by RINA with drawing No. SHEL-29761.
+ Test Report: “Shanghai National center of testing and inspection for electric cabel and wire Co., Ltd.” Report No.: CT25-03995-2B1. Test Report: “Shanghai Intelligent Service and Technology Co., Ltd.” Report No.: TN25-5208E. Filed by RINA with drawing No. SHEL-29766.
+ Routine test Report and Narrative report signed by RINA Surveyor. Filed by RINA with drawing No. SHEL-29765.
+ Asbestos-free Declaration: Filed by RINA with drawing No. SHEL-29753.
+ Manufacturer's information, Filed by RINA with drawing No. SHEL-29755.
3. Notes/Remarks:
+ The product is subject to the compliance with RINA Rules and Standards mentioned on the certificates.
+ Type Approval certifies that a representative sample of the product has been found to meet the applicable design criteria.
+ Any modification or change shall not be valid until approval is granted by RINA as a result of due assessment. |
|