1. Product Description
+ Shipboard Bus cable type and parameters.
| Parameter /Type | RG 6 | RG 11 | RG 59 | RG 58 | RG 213 | RG 214 |
| Conductor | Bare Cu | Tinned Cu | Silver plated copper |
| Insulation | Foamed PE | Solid PE |
| Shield | AL + polyester tape + AL | - | Silver-coated |
| Screen | Tinned Cu-braid |
| Jacket (mm) | SHF1/SHF2/SHF-MUD/SHF-FI |
| Armour(Optional) | Tinned Cu-braid |
| Outer Jacket | SHF1/SHF2/SHF-MUD/SHF-FI |
+ Electrical Characteristics (20 ℃)
| RG 6 | RG 11 | RG 59 | RG 58 | RG 213 | RG 214 |
Impedance | 75±3Ω | 75±3Ω | 75±3Ω | 50±2Ω | 50±2Ω | 50±2Ω |
Capacitance | 54 pF/m | 54 pF/m | 54 pF/m | 101 pF/m | 101 pF/m | 101 pF/m |
Propagation velocity | 82% | 84% | 81% | 66% | 66% | 66% |
Resistance inner conductor | 22.2 Ω/km | 8.7 Ω/km | 154 Ω/km | 37.5 Ω/km | 6 Ω/km | 5.8 Ω/km |
Resistance Outer conductor | 14.0 Ω/km | 9.0 Ω/km | 9 Ω/km | 16.5 Ω/km | 4 Ω/km | 4.2 Ω/km |
Insulation resistance | ≥5000MΩ·km | / | / | / |
Tension sheath spark test | 2.5KV | 4 KV | 2.5 KV | 4 KV | 5 KV | 5.5 KV |
+ Properties’ suffix:
SHF1: Low Smoke, Zero Halogen, Flame retardant
SHF2 : Low Smoke , Zero Halogen, Flame retardant, Oil resistance
SHF-FI : Low Smoke , Zero Halogen, Flame retardant, Fire-resistant
SHF-MUD : Low Smoke , Zero Halogen, Flame retardant, Mud resistance
+ Install at: -20℃ to 60℃
+ Operate at: -40℃ to 90℃
Enclosure - Page 2 of 3
+ Transmission Characteristics:
Frequencu(MHZ) | Attenuation(@20℃dB/100m) |
RG 6 | RG 11 | RG 59 | RG 58 | RG 213 | RG 214 |
5 | 1.80 | 1.30 | 2.40 | 3.30 | 1.10 | 1.40 |
10 | 2.50 | 1.50 | 3.00 | 4.70 | 1.50 | 2.00 |
50 | 5.25 | 3.15 | 6.73 | 10.90 | 3.80 | 4.80 |
100 | 8.10 | 6.10 | 10.00 | 15.60 | 5.50 | 6.80 |
200 | 10.20 | 6.23 | 12.47 | 22.60 | 8.00 | 10.00 |
300 | 11.64 | 7.38 | 14.60 | 28.10 | 10.10 | 12.80 |
500 | 15.10 | 9.81 | 17.72 | 37.10 | 13.20 | 17.10 |
600 | 16.34 | 10.98 | 19.52 | 40.95 | 14.80 | 19.10 |
800 | 19.00 | 12.95 | 22.87 | 48.30 | 17.50 | 23.00 |
1000 | 21.49 | 14.67 | 24.67 | 54.90 | 20.00 | 26.50 |
1350 | 25.22 | 17.37 | 26.64 | 65.50 | 23.90 | 32.00 |
1500 | 26.85 | 18.72 | 43.40 | 69.80 | 25.30 | 34.50 |
1750 | 28.67 | 20.12 | 47.70 | 76.80 | 27.90 | 37.50 |
2150 | 31.91 | 22.68 | 54.10 | 87.18 | 31.50 | 42.80 |
2250 | 32.81 | 23.50 | 55.00 | 89.80 | 32.40 | 44.00 |
2500 | 35.20 | 25.52 | 58.10 | 96.30 | 34.70 | 47.00 |
2750 | 37.30 | 26.95 | 61.30 | 102.50 | 36.70 | 50.50 |
3000 | 38.70 | 28.50 | 65.90 | 108.50 | 38.30 | 54.00 |
dB(MHZ)
Structural return loss | RG 6 | RG 11 | RG 59 | RG 58 | RG 213 | RG 214 |
30—300 | ≥23 | ≥23 | ≥20 | ≥23 | ≥23 | ≥23 |
300—600 | ≥23 | ≥23 | ≥20 | ≥21 | ≥21 | ≥21 |
600—1000 | ≥23 | ≥20 | ≥20 | ≥20 | ≥20 | ≥20 |
1000—2000 | ≥20 | ≥14 | ≥18 | ≥18 | ≥18 | ≥18 |
2000—3000 | ≥18 | ≥10 | ≥15 | ≥14 | ≥15 | ≥15 |
dB(MHZ)
Screening effectiveness | RG 6 | RG 11 | RG 59 | RG 58 | RG 213 | RG 214 |
100—900 | ≥62 |
900—2000 | ≥65 |
2000--3000 | ≥55 |
Enclosure - Page 3 of 3
2. Test standards:
+ IEC 61196-1-2005; IEC 60096-0-1-2012;IEC 60092-360-2021; NEK606-2022; IEC 60331-23-1999;
IEC60332-1-2-2015;IEC 60332-3-22-2018; IEC60754-1-2019; IEC60754-2-2019;IEC 61034-1-2019;
IEC61034-2-2019;IEC60684-2-2011;UL1581.
3. Reference Documents:
+ Declaration for the manufacturer address signed by our attending Surveyor. Filed by RINA with drawing No.: SHEL-21688.
4. Notes/Remarks:
+ The product is subject to the compliance with RINA Rules and Standards mentioned on the certificates.
+ Type Approval certifies that a representative sample of the product has been found to meet the applicable design criteria.
+ Any modification or change shall not be valid until approval is granted by RINA as a result of due assessment.
5. Renewal/Revision
+ May 9, 2023: initial certification. Certificate No. ELE089923WS/003.
+ December 19, 2024: renewed without design change. New certificate No. ELE587524WS/003 revokes previous certificate. |
|