Intended Service
Programmable Logic Controllers and I/O devices for control, monitoring, alarm and safety functions for internal
combustion engines and selective catalytic reduction system and ship automation system.
Description
Gateway Module
Module Type
Name: SaCoSone Gateway Module - GM V1.6/GM-D2R401; GM V1.7/GM-D2R401 (cyber secure version)
Ratings
Power supply: 24 V DC
Ambient temperature: -10°C to 75°C
Class of protection: IP
- 4 CAN
- 1 RS485
- 2 Ethernet ports
Firmware version:
SaCoSone GM_ Firmware_1.4.2_xx; GM_Firmware_1.5.0_xx (cyber secure version)
Reference Documents:
- SaCoSone.GM,MasterDocTypeApp,EN dated 06.07.2023
- SaCoSone.GM.HW,ProductSpec,Internal,EN dated 15.10.2019
- SaCoS,Modules,TestSpecTypeApp,EN dated May 2023
- Climatic Rpt+SaCos One Gateway Module Gateway Module GM 1,6 dated 31.05.2023
- EMC Compliance Report CE+SaCos GM D2 R400 dated 29.06.2023
- Mechanic Rpt+SaCos One Gateway Module Gateway Module GM 1,6 dated 20.06.2023
- GM,SAFETY,Firmware,ReleaseNotes dated 15.12.2023
- GM,Firmware,ReleaseNotes dated 15.12.2023
Remarks:
- limitations as outlined by the Technical requirements
The acceptance on board for each installation is subordinated to the submission to the approval of the following documentation:
- System Block Diagram and SaCoS Hardware Configuration for the specific Diesel Engine / Ship propulsion
plant
- Dedicated FMEA and on board test schedule including the List for inspection of the alarm, safety and injection
control systems, in order to verify the compliance with SOLAS requirement Chapter II-1 - Rule 49
- Software version is to be available
CERTIFICATE RETENTION:
All changes in software and hardware are to be recorded as long as the system is in use on board.
The records of all changes are to be forwarded to RINA for evaluation and approval.
Major changes in the software / firmware are to be approved before being installed on the programmed systems.