Type | MBS 33M | MBS 3300/3350 | MBS 9300 |
Measuring Range | 0…1 to 0…600bar | 0...1 to 0...600bar | -70 to 250mbar |
Supply Voltage | 9 – 32 V DC (12 / 24 V DC nom.) | 9 – 32 V DC; 15 – 32 V DC (12 / 24 V DC nom.); 4.5 – 5.5 V DC
(5 V DC nom.)
| 9 – 32 V DC; 5 V DC +/- 10% |
Output Signal | 4...20 mA | 4 - 20 mA; 0 - 5 V; 1 - 5 V; 1 - 6 V; 0 - 10 V; 10 - 90% of supply voltage | 4 – 20 mA;
Ratiometric 10-90% supply
|
Accuracy (incl. non-linearity, hysteresis and repeatability) | ≤ ± 0.3% FS (typ.)
≤ ± 0.8% FS (max.)
| ≤ ± 0.5% FS (typ.)
≤ ± 1.0% FS (max.)
| Between ≤ ± 2 % FSS and ≤ ± 0.5 % FSS according to value range |
Enclosure/Wetted Parts | AISI 316L | AISI 316L | AISI 316L |
Sensor Operating temperature | Normal: -40 – 85 °C
ATEX Zone 2: -20 – 85 °C
| 4 – 20 mA: -40 – 100 °C
10 – 90% of supply voltage, 0 – 5 V, 1 – 5 V, 1 – 6 V, 0 – 10 V: -40 – 125 °C
|
|
Medium Temperature | -40 – 85 °C | -40 – 125 °C | FPM gasket: -20°C – 100°C
NBR gasket: -25 °C – 85 °C
|
Compensated Temperature | 0 – 80 °C | 0 – 100 °C | 0 – 80 °C |
Insulation Resistance | > 100 Mohm at 500 V DC | > 100 Mohm at 500 V DC |
|
Vibration Stability | Sinusoidal: 15.9 mm-pp, 5 Hz – 25 Hz 20 g, 25 Hz – 2 kHz
Random: 7.5 grms, 5 Hz – 1 kHz
| Sinusoidal: 15.9 mm-pp, 5 Hz – 25 Hz 20 g, 25 Hz – 2 kHz
Random: 7.5 grms, 5 Hz – 1 kHz
| Sinusoidal: 15.9 mm-pp, 5 Hz – 25 Hz 20 g, 25 Hz – 2 kHz
Random: 7.5 grms, 5 Hz – 1 kHz
|
Shock Resistance | Shock: 500 g / 1 ms
Free fall: 1 m
| Shock: 500 g / 1 ms
Free fall: 1 m
| Shock: 500 g / 1 ms
Free fall: 1 m
|
Enclosure | IP65 / IP67 | IP54 / IP65 / IP67 | IP65 |
Ambient Temperature | Between -40 and 85 °C according to type | Between -40 and 125 °C according to type | -25 °C – 100 °C (ATEX zone 2 = -10 °C – 85 °C) |