  Marine Equipment(TO)
MED873326WS
Certification N. MED447623WS - (ENG)
Certificate date 28/04/2025
Type Prevenzione dell'inquinamento marino
Product Sewage systems: (a) for use by passenger ships in all areas, including a MARPOL Annex IV special area
Item Nº MED/2.6a

Model or Denomin.
Items
CSWD series
Applicant Shanghai Shijiu Marine Equipment Co., Ltd.
Place of requester Building 43, No.193 Nanlu Road, Pudong  %  201314 Shanghai  % CHINA
Tel. N.,Fax, Email 13917848174, 021-68539559, jiyi@shijiumarine.com
Directive (EU) 2024/1975
Standards IMO Res.MEPC.227(64), including section 4.2.
Reference Documents Annex IV Regulation 9(1) of Marpol 73/78, as amended, RINA Rules for the certification of Marine Equipment
Expire date 27/04/2030
Responsible Office RINA China Marine
EC TYPE-EXAMINATION (MODULE B) ENG
Vuoto Querysave
Qiang Sun S

EC TYPE EXAMINATION (MODULE B)
CERTIFICATE No. MED447623WS

This is to certify that RINA Services S.p.A. (Notified Body No. 0474) did undertake the relevant type approval procedures for the equipment identified below, which was found to be in compliance with the Marine-Pollution prevention requirements of Marine Equipment Directive (MED) 2014/90/EU, including the requirements and testing standards of Regulation (EU) 2024/1975.
MED Item Nº MED/2.6a
Description Sewage systems: (a) for use by passenger ships in all areas, including a MARPOL Annex IV special area
Type CSWD series
Applicant Shanghai Shijiu Marine Equipment Co., Ltd.
Building 43, No.193 Nanlu Road, Pudong,201314 Shanghai,CHINA
Testing standards IMO Res.MEPC.227(64), including section 4.2.
Reference standards Annex IV Regulation 9(1) of Marpol 73/78, as amended, RINA Rules for the certification of Marine Equipment
Issued in RINA China Marine on
This Certificate is valid until
April 28, 2025
April 27, 2030
This Certificate consists of this sheet plus an attachment

________________________________________
Qiang Sun
RINA Services S.p.A.
**** NOTICE: This is NOT an official certificate ****

ATTACHMENT TO
CERTIFICATE No.  MED447623WS
Page 1 of 5
Reference documents
CSWD Series(0.8~70) Sewage treatment plants manufactured according to the Shanghai Shijiu Marine
Equipment CO., LTD technical specification and Drawings with RINA Approved No. SHMC-26801~26802 and SHMC-26805~26807.

Type approval test program prepared by manufacturer and reviewed with RINA No.SHMC-26803;SHMC-26797 and SHMC-26798

Influent/effluent samples Testing Report No.:HJ2100000219RR; HJ2100000220RR; HJ2100000223RR; HJ2100000224RR; HJ2100000244RR; HJ2100000246RR; HJ2100000273RR; HJ2100000286RR carried out by Ningbo Customs District Technology Center dated from 05/08/2021 to 22/08/2021.

Environmental Testing Reports carried out by China Waterborne Transport Research Insitute dated from 17/08/2021 to 26/08/2021 and from 29/10/2021 to 04/11/2021 as followings(No.): WT-2021-010(1)-DQ; WT-2021-010(2)-DQ.

Environmental Testing Reports carried out by Unilab(Shanghai) Testing Technology Co.,Ltd dated 30/08/2023 as followings: UL145420230627001

Technical characteristics
CSWD series(0.8~70) sewage treatment plants adopts a combination of oxidation degradation, microfiltration, electrocatalysis to treat sewage.

Model: CSWD Series
Capacity(m3/day)
Organic load(kg/day)
CSWD-0.8
0.8
0.4
CSWD-1.5
1.5
0.75
CSWD-2.1
2.1
1.05






ATTACHMENT TO
CERTIFICATE No. MED447623WS
Page 2 of 5

Model: CSWD Series
Capacity(m3/day)
Organic load(kg/day)
CSWD-2.8
2.8
1.4
CSWD-4.5
4.5
2.25
CSWD-5.5
5.5
2.75
CSWD-7
7
3.5
CSWD-10
10
5
CSWD-12
12
6
CSWD-15
15
7.5
CSWD-20
20
10
CSWD-25
25
12.5
CSWD-30
30
15
CSWD-35
35
17.5
CSWD-40
40
20
CSWD-45
45
22.5
CSWD-50
50
25
CSWD-60
60
30
CSWD-70
70
35

Discharge standard within the following limits:

Thermotolerant Coliforms (geometric mean)
Less than 100 cells/100ml
5-day Biochemical Oxygen Demand(BOD5)
Less than 25 mg/l
Chemical Oxygen Demand (COD)
Less than 125 mg/l
Total Suspended Solids (TSS)
Less than 35mg/l
PH value
Between 6.0 and 8.5
Total nitrogen
Less than 20 mg/l
Total phosphorus
Less than 1.0 mg/l


Field of application
Each sewage treatment plant is to be supplied with it's manual for installation, use and maintenance.
The installation on board is to be carried out in accordance with manufacturer's instructions.
A copy of this EC type-examination certificate shall be carried on board any ship, equipped with the above
discribed sewage treatment plant at all times.
Limitations and conditions of operation are imposed as follows: Inclination less than 22.5 degrees and
Viabration 2 to 13.2Hz with an amplitude of plus or minus 1mm and 13.2 to 80 Hz with an acceleration of plus
or minus 0.7g.

Marking of product
A plate or durable label shall be placed on the sewage treatment plant with at least the following information:
-Manufacturer's name or logo
-Model and serial number
-Hydraulic loading








ATTACHMENT TO
CERTIFICATE No. MED447623WS
Page 3 of 5




APPENDIX TO CERTIFICATE OF TYPE APPROVAL FOR SEWAGE TREATMENT PLANTS

Test results and details of tests conducted on samples from the sewage treatment plant in accordance with resolution MEPC.227(64), as amended:



Sewage treatment plant, Type: .........................................................CSWD-1.5&CSWD-7
Manufactured by: ..............................................................Shanghai Shijiu Marine Equipment Co.,Ltd
Organization conducting the test: ......................................Ningbo Customs District Technology Center
Designed hydraulic loading: ..................................................1.5 & 7................ .....m³/day
Designed organic loading: ................................................0.75 & 3.5................. kg/day BOD

Number of effluent samples tested: ..............................................40.........................
Number of influent samples tested: .................................................40......................
Total suspended solids influent quality: ............. ........................>500......................mg/l
Total nitrogen influent quality.....................................................>100.........mg/l as nitrogen
Total phosphorus influent quality............................................>20........mg/l as phosphorus

BOD5 without nitrification influent quality: .............................>500.............................mg/l
Maximum hydraulic loading: ..................................1.5 &7..................................... m³/day
Minimum hydraulic loading: .......................................1.5 &7................................. m³/day
Average hydraulic loading (Qi): ...............................1.5 &7.................................... m³/day
Effluent flow (Qe):...............................................1.5 &7 ........................................... m³/day
Dilution compensation factor (Qi/Qe):...................................1.....................................
Geometric mean of total suspended solids: ................................1.99/2.77.......................mg/l
Geometric mean of the thermotolerant coliform count:............<20....... coliforms/100 ml
Geometric mean of BOD5 without nitrification: .....................12.52/9.29............................ mg/l
Geometric mean of COD: ......................64.42/46.05.......................... mg/l
Geometric mean of total nitrogen ............................4.67/3.8.................................mg/l
Geometric mean of total phosphorus.........................0.09/0.04...............................mg/l
Maximum pH: .....................6.9/6.9...........................
Minimum pH: .....................6.3/6.4...........................














ATTACHMENT TO
CERTIFICATE No. MED447623WS
Page 4 of 5



Type of disinfectant used: ....................................electrolytic ........................................
If Chlorine - residual Chlorine:
Maximum:.......................................0.49/0.69.............................................. mg/l
Minimum: ........................................0.15/0.17.............................................. mg/l
Geometric Mean: .........................0.31/0.35................................................. mg/l

Was the sewage treatment plant tested with:
Fresh water flushing? ............................................................. Yes
Salt water flushing? ................................................................ Yes
Fresh and salt water flushing? ............................................... Yes
Grey water added? ......................................... Yes

Was the sewage treatment plant tested against the environmental conditions specified in section 5.9 of resolution MEPC.227(64):
Temperature? ........................................................................... Yes
Humidity?.................................................................................. Yes
Inclination? ................................................................................ Yes
Vibration? .................................................................................. Yes
Reliability of Electrical and Electronic Equipment? .................... Yes

Limitations and the conditions of operation are imposed:
Salinity ...............................................<=35g/L.................................................
Temperature ...........................................as per Part 3,MEPC.107(49)............................
Humidity ...............................................as per Part 3,MEPC.107(49)...................................
Inclination .....................................................as per Part 3,MEPC.107(49) ............................
Vibration .............................................................as per Part 3,MEPC.107(49) ...........................

Results of other parameters tested ................................/ .......................................




ATTACHMENT TO
CERTIFICATE No. MED447623WS
Pages 5 of 5
The mark of conformity may only be affixed to the above type approved equipment and a Manufacturer's Declaration of Conformity issued when the production control phase module (D, E or F) of Annex II of the Directive is fully complied with a written inspection agreement with a Notified Body
XXXX/YY
"WHEELMARK FORMAT"

XXXX
Notified Body number undertaking surveillance module
YY
Last two digits of year mark affixed
     
______________________________________________
General conditions for the approval
a) The initial conditions verified by RINA at the time of the approval are to be maintained
b) Any changes to the initial conditions are to be promptly communicated to RINA, which reserves the right to repeat the relevant assessment
c) This certificate will no be valid if the manufacturer makes any changes or modifications to the approved equipment, which have not been notified to, and agreed with RINA
d) RINA personnel are to be allowed to witness during the performances of activities, upon their request
e) The activities are to be carried out in compliance with the RINA Rules and/or other applicable Rules

f) Should the specified regulations or standards be amended during the validity of this certificate, the product is to be reapproved prior to it being placed on board vessels to which the amended regulations or standards apply. 


__________________________________________
Qiang Sun
**** NOTICE: This is NOT an official certificate ****