Certification N. MED260822WS - (ENG)
Certificate date 12/06/2023
Type Protezione antincendio
Product Fixed water-based fire-fighting systems for ro-ro spaces, vehicle spaces and special category spaces: (a) prescriptive-based systems as per IMO MSC.1/Circ.1430, Revision 2
Item Nº MED/3.49a

Model or Denomin.
Items
FTCM
Applicant SHANGHAI FIRETEC MECHATRONIC ENGINEERING CO., LTD.
Place of requester No. 518 Xuanxia Road, Pudong New District, Shanghai  % CHINA
Tel. N.,Fax, Email +86 21 58627886, +86 21 58627765, factory@firetecmarine.com
Directive (EU) 2022/1157
Standards IMO MSC.1/Circ.1430, Revision 2.
Reference Documents SOLAS 74 Reg. II-2/19, SOLAS 74 Reg. II-2/20, IMO Res. MSC.36(63)-(1994 HSC Code) 7, IMO Res. MSC.97(73)-(2000 HSC Code) 7, IMO Res. MSC.98(73)-(FSS Code) 7.
Request 2022/05/28
Expire date 11/06/2028
Head Office SHANGHAI
EC TYPE-EXAMINATION (MODULE B) ENG
Vuoto Querysave
Qiang Sun S

EC TYPE EXAMINATION (MODULE B)
CERTIFICATE No. MED260822WS

This is to certify that RINA Services S.p.A. (Notified Body No. 0474) did undertake the relevant type approval procedures for the equipment identified below, which was found to be in compliance with the Fire Protection requirements of Marine Equipment Directive (MED) 2014/90/EU, including the requirements and testing standards of Regulation (EU) 2022/1157.
MED Item Nº MED/3.49a
Description Fixed water-based fire-fighting systems for ro-ro spaces, vehicle spaces and special category spaces: (a) prescriptive-based systems as per IMO MSC.1/Circ.1430, Revision 2
Type FTCM
Applicant SHANGHAI FIRETEC MECHATRONIC ENGINEERING CO., LTD.
No. 518 Xuanxia Road, Pudong New District, Shanghai,CHINA
Testing standards IMO MSC.1/Circ.1430, Revision 2.
Reference standards SOLAS 74 Reg. II-2/19, SOLAS 74 Reg. II-2/20, IMO Res. MSC.36(63)-(1994 HSC Code) 7, IMO Res. MSC.97(73)-(2000 HSC Code) 7, IMO Res. MSC.98(73)-(FSS Code) 7.
Issued in SHANGHAI on
This Certificate is valid until
June 12, 2023
June 11, 2028
This Certificate consists of this sheet plus an attachment

________________________________________
Qiang Sun
RINA Services S.p.A.
**** NOTICE: This is NOT an official certificate ****

ATTACHMENT TO
CERTIFICATE No.  MED260822WS
Page 1 of 4

Product Description


The FTCM Series Nozzles are non-automatic nozzles with open spray head made of Brass or Stainless Steel used in Fixed Water-based Fire-fighting Systems which is designed in accordance with the "Principal Requirements" of IMO MSC.1/Circ.1430, Rev.2, for prescriptive-based system, the system consists of nozzles and section valves in addition to pump unit(s), steel piping, control system as associated equipment.

Only the nozzles are type approved by this certificate. Pumps, pipes, couplings, valves and other systems components are subject to case-by-case approval.

The nozzles were designed with the following types and main characteristics:

Nozzle
Types
K
Factor
Working Pressure
Spray
Angle
Connection
(Male Thread)
Min. (bar)
Max. (bar)
FTCM-K-19
19
1.4
10.0
60°
80°
100°
120°
140°
160°
BSPT1/2"
(Nozzle thread can be customized to NPT1/2")
FTCM-K-27
27
FTCM-K-33
33
FTCM-K-42
42
FTCM-K-61
61
FTCM-K-80
80
FTCM-K-98
98
FTCM-K-109
109
FTCM-K-120
120
The flow rate and flow profile refer to the nozzle datasheet.
The nozzles are to be installed in a downward position.

Fields of Application/Limitation

Nozzles are designed/approved for directional spray applications only used in Fixed Water-based Fire-fighting Systems for Ro-Ro Spaces, Vehicle Spaces and Special Category Spaces.

System design and installation shall be in accordance with principal requirements and prescriptive-based system requirements of IMO MSC.1/Circ.1430, Revision 2, Ch.3 and 4. In addition, uniform distribution of nozzles inside protected space as well as overlap of the spray pattern shall be ensured.

ATTACHMENT TO
CERTIFICATE No. MED260822WS
Page 2 of 4
Continued:

Reference Documents

Technical drawings, datasheet edit by Shanghai Firetec Mechatronic Engineering Co.,Ltd as folloiwing:

1. Technical drawing for FTCM Nozzles approved by RINA with No.: SHFP-23328;


2. Technical datasheet for FTCM Nozzles approved by RINA with No.: SHFP-23329;
3. Typical system calculation for deluge fire-fighting system approved by RINA with No.: SHFP-22963.

Production and Tests Carried Out

The tests for the Nozzles had been carried out in accordance with IMO MSC/Circ.1165:

1. Visual Examination Test Report carried out by Shanghai Firetec Mechatronic Engineering Co.,Ltd dated on July.31 2022, and filed by RINA with No.: SHFP-23437;


2. Functional Test Report carried out by Shanghai Firetec Mechatronic Engineering Co.,Ltd dated on July.25 2022, and filed by RINA with No.: SHFP-23438;
3. Flow Test Report carried out by Shanghai Firetec Mechatronic Engineering Co.,Ltd dated on July.26 2022, and filed by RINA with No.: SHFP-23428;
4. Stress Corrosion Test Report (Ref. No.: WX220520-026-01) for Brass Nozzles carried out by Wuxi RELLAB Testing Service Co., Ltd dated on August.11 2022, and filed by RINA with No.: SHFP-23429;
5. Stress Corrosion Cracking Test Report (Ref. No.: FCT220923-01) for Stainless Steel Nozzles carried out by Shanghai Firetec Mechatronic Engineering Co.,Ltd dated on September.23 2022, and filed by RINA with No.: SHFP-23430;
6. Sulphur Dioxide Corrosion Test Report (Ref. No.: FTC220913-01) carried out by Shanghai Firetec Mechatronic Engineering Co.,Ltd dated on September.13 2022, and filed by RINA with No.: SHFP-23431;
7. Salt Spray Corrosion Test Report (Ref. No.: WX220520-026-02-G1) carried out by Wuxi RELLAB Testing Service Co., Ltd dated on August.24 2022, and filed by RINA with No.: SHFP-23432;
8. Moist Air Exposure Test Report(Ref. No.: FTC220913-09) carried out by Shanghai Firetec Mechatronic Engineering Co.,Ltd dated on April.20 2023, and filed by RINA with No.: SHFP-23433;
9. Heat-resistance Test Report (Ref. No.: WX220520-026-03) carried out by Wuxi RELLAB Testing Service Co., Ltd dated on August.11 2022, and filed by RINA with No.: SHFP-23434;
10. Vibration Test Report carried out by Shanghai Firetec Mechatronic Engineering Co.,Ltd dated on July.29 2022, and filed by RINA with No.: SHFP-23435;
11. Impact Test Report (Ref. No.: WX220520-026-04) carried out by Wuxi RELLAB Testing Service Co., Ltd dated on August.11 2022, and filed by RINA with No.: SHFP-23436.

Installation Testing

The installation tests are to be carried out as following:

1. System shall be cleaned as per the routines outlined in maker’s system description manual.


2. For deluge system, it should be tested for the simultaneous activation of the at least two(2) adjacent sections with full flow through the nozzles at the minimum water discharge density.
3. Testing of manual and remote release of all section valves (without water accepted).
4. Testing of manual and remote start of pumps.
5. Testing of the alarms at the manned control stations.
6. Other tests as required by Class Rules (pressure testing of piping, etc.) or a similar standard acceptable to the Flag Administration and according to maker's manual shall be carried out.

ATTACHMENT TO
CERTIFICATE No. MED260822WS
Page 3 of 4
Continued:

Marking of the Product

The Nozzles shall be marked with the name of the manufacturer and the type designation as indicated in this certificate.

Remarks

1. Installation of the of nozzles shall be in accordance with the type approval documentation.
2. Prior to fitting the system on board, the following details shall be submitted for approval for each separated case:
- Schematic arrangement of the system of jointing nozzles type, sections valves, release stations and pump units, etc.;
- Electrical wiring system including power supply system and system control system;
- System dimensioning and hydraulic calculations;
- Specifications of Pumps, pipes, couplings, valves and other systems components;
- Design, installation, operation and maintenance manual.




ATTACHMENT TO
CERTIFICATE No. MED260822WS
Pages 4 of 4
The mark of conformity may only be affixed to the above type approved equipment and a Manufacturer's Declaration of Conformity issued when the production control phase module (D, E or F) of Annex II of the Directive is fully complied with a written inspection agreement with a Notified Body
XXXX/YY
"WHEELMARK FORMAT"

XXXX
Notified Body number undertaking surveillance module
YY
Last two digits of year mark affixed
     
______________________________________________
General conditions for the approval
a) The initial conditions verified by RINA at the time of the approval are to be maintained
b) Any changes to the initial conditions are to be promptly communicated to RINA, which reserves the right to repeat the relevant assessment
c) This certificate will no be valid if the manufacturer makes any changes or modifications to the approved equipment, which have not been notified to, and agreed with RINA
d) RINA personnel are to be allowed to witness during the performances of activities, upon their request
e) The activities are to be carried out in compliance with the RINA Rules and/or other applicable Rules

f) Should the specified regulations or standards be amended during the validity of this certificate, the product is to be reapproved prior to it being placed on board vessels to which the amended regulations or standards apply. 


__________________________________________
Qiang Sun
**** NOTICE: This is NOT an official certificate ****