MED495225CS!002ENGF- -  -  N- OMP50A60X.D_LL (A60) -N- S- S- -18/06/2026- Marine Equipment- - SN- S- - N-  - 123,543B2bisMarine EquipmentNumero Pratica,Direttiva,Norma,Schema,Richiesta,Validità,EmailR- MED495225CS/002- N-Jun 17, 2031123543
 
Form
  Marine Equipment(TO)
Certification N. MED495225CS/002 - (ENG)
Certificate date 18/06/2026
Type Protezione antincendio
Product Porte tagliafuoco
Item Nº MED/3.16
USCG Category N° 164.136

Model or Denomin.
Items
OMP50A60X.D_LL (A60)
Applicant MECCANICA MARIANI SRL
Place of requester VIA PIAN DI CELLE. 51  %  05010 San Venanzo (TR)  % ITALY
Tel. N.,Fax, Email 075 875210, 075875557, direzione@meccanicamariani.it
Directive (EU) 2025/1533
Standards IMO Res. MSC.307(88)-(2010 FTP  Code), as amended.,IMO MSC.1/Circ.1319
Reference Documents SOLAS 74 Reg.II-2/9, IMO MSC.1/Circ.1511/Rev.1
Request 18/06/2026
Expire date 17/06/2031
EC TYPE-EXAMINATION (MODULE B) ENG
Vuoto Querysave
Enrico Cabella S

EC TYPE EXAMINATION (MODULE B)
CERTIFICATE No. MED495225CS/002

This is to certify that RINA Services S.p.A. (Notified Body No. 0474) did undertake the relevant type approval procedures for the equipment identified below, which was found to be in compliance with the Fire Protection requirements of Marine Equipment Directive (MED) 2014/90/EU, including the requirements and testing standards of Regulation (EU) 2025/1533.
MED Item Nº MED/3.16
USCG Category Nº 164.136
Description Fire doors
Type OMP50A60X.D_LL (A60)
Applicant MECCANICA MARIANI SRL
VIA PIAN DI CELLE. 51,05010 San Venanzo (TR),ITALY
Testing standards IMO Res. MSC.307(88)-(2010 FTP  Code), as amended.,IMO MSC.1/Circ.1319
Reference standards SOLAS 74 Reg.II-2/9, IMO MSC.1/Circ.1511/Rev.1
Issued in Genoa on
This Certificate is valid until
June 18, 2026
June 17, 2031
This Certificate consists of this sheet plus an attachment

________________________________________
Enrico Cabella
RINA Services S.p.A.
**** NOTICE: This is NOT an official certificate ****

ATTACHMENT TO
CERTIFICATE No.  MED495225CS/002
Page 1 of 2

Product description


Double leaf hinged door whose clear opening size is 1890 mm high and 1500 mm wide. The door leaves, having thickness of 116 mm, height of 1970 mm and width of 610 mm (secondary leaf) and 957.5 (primary leaf), are composed, starting from the side with the hinges unexposed to the fire, of a 4 mm thick carbon steel plate, an insulation package consisting of two layers of material type PROMAGUARD, 10 and 6 mm thick and having density of 240 kg/m3 fixed to the carbon steel sheet having thickness of 2 mm by means of steel pins and washers welded with density of 12 per m2. The leaves are fitted, inside, with T shaped carbon steel stiffeners having dimensions of 40x40 mm and thickness of 6 mm, welded to the steel plate having thickness of 4 mm. The secondary leaf is equipped with No. 1 vertical stiffener and No. 6 horizontal stiffeners, having a pitch of 320 mm, whereas the primary leaf is equipped with No. 2 vertical stiffeners, having a pitch of 300 mm and with No. 6 horizontal stiffeners, having a ranging pitch from 261 mm to 455 mm; the coupling of the outer sheet with the inner sheet is achieved by means of stainless-steel screws M5 having a ranging pitch from 335 to 562 mm. The door frame consists of an “L” shaped carbon steel profile having dimensions of 100 X 75 mm with a thickness of 7 mm, fixed to the aluminum bulkhead by No. 49 M16 stainless-steel bolts with a ranging pitch from 80 to 322 mm. The frame is insulated on both sides, for a width of 85 mm, with 2 layers of mineral wool Rockwool type SeaRox SL620, thickness 30 mm and density 100 kg/m³, fixed with pins and washers. Between frame and aluminium bulkhead is provided a corde of sealant Sika type Firestop Marine in correspondence of the bolts and a layer of intumescent gasket PROMAT type PROMASEAL-PL having thickness of 2.5 mm and width of 15 mm. On the rebate of the doors between leaves and frame is provided 1 layer of intumescent gasket PROMAT type PROMASEAL-PL having thickness of 2.5 mm and width of 15 mm. The closure is made tight with an EPDM gasket UNIGUM type SPS040T having dimensions of 30x20 mm type fitted in the bended edge on the rabbet which is shielded with 2 thermo-expanding gaskets PROMAT type PROMASEAL-PL having thickness of 2.5 mm and width of 15 mm fitted on exposed to the fire perimetric doors edge. The leaves are provided of 2 hinges. The secondary leaf is fitted with No. 5 external closure points welded to the frame; the primary leaf is equipped with a lever closing device, that acts on 10 points, fitted inside the leaf and actuated by the removable handle, provided on both sides.
Field of application

Fire resistant A-60 Class double leaf hinged door intended for general applications installed on an aluminium bulkhead.

In case of doors in compliance to the "Agreement between the European Community and the United States of America", the present certificate is valid at the following conditions:
- maximum door size tested;
- door used with a fire tested frame design.
Reference documents

Meccanica Mariani drawings No. B-6374-900-149_LL_TEST dated 31/10/2025 reported on Test as per RINA Fire Protection Laboratory report No. 2025CS014952/2 issued on 17 June 2026.
Tests carried out

Test as per RINA Fire Protection Laboratory report No. 2025CS014952/2 issued on 17 June 2026 according to IMO 2010 FTP Code Part 3.




ATTACHMENT TO
CERTIFICATE No. MED495225CS/002
Pages 2 of 2
The mark of conformity may only be affixed to the above type approved equipment and a Manufacturer's Declaration of Conformity issued when the production control phase module (D, E or F) of Annex II of the Directive is fully complied with a written inspection agreement with a Notified Body
XXXX/YY
"WHEELMARK FORMAT"

XXXX
Notified Body number undertaking surveillance module
YY
Last two digits of year mark affixed
     
______________________________________________
General conditions for the approval
a) The initial conditions verified by RINA at the time of the approval are to be maintained
b) Any changes to the initial conditions are to be promptly communicated to RINA, which reserves the right to repeat the relevant assessment
c) This certificate will no be valid if the manufacturer makes any changes or modifications to the approved equipment, which have not been notified to, and agreed with RINA
d) RINA personnel are to be allowed to witness during the performances of activities, upon their request
e) The activities are to be carried out in compliance with the RINA Rules and/or other applicable Rules

f) Should the specified regulations or standards be amended during the validity of this certificate, the product is to be reapproved prior to it being placed on board vessels to which the amended regulations or standards apply. 


__________________________________________
Enrico Cabella
**** NOTICE: This is NOT an official certificate ****