MED491525CSENGB- -  -  N- SSF-A60 -N- S- S- -07/11/2025- Marine Equipment- - SN- S- - N-  - 883,804B2bisMarine EquipmentNumero Pratica,Direttiva,Norma,Schema,Richiesta,Validità,EmailR- MED491525CS- N-Nov 6, 2030883804
 
Form
  Marine Equipment(TO)
MED491525CS
Certification N. MED491525CS - (ENG)
Certificate date 07/11/2025
Type Protezione antincendio
Product Porte tagliafuoco
Item Nº MED/3.16
USCG Category N° 164.136

Model or Denomin.
Items
SSF-A60
Applicant CARETTA INTERIORS AE
Place of requester THESI MAURI ORA, INDUSTRIAL AREA OF ASPROPYRGOS  %  19300 ATHENS  % GREECE
Tel. N.,Fax, Email +30 210 6621506, +30 210 6621507, caretta.interiors@gmail.com
Directive (EU) 2025/1533
Standards IMO Res. MSC.307(88)-(2010 FTP  Code), as amended.,IMO MSC.1/Circ. 1319
Reference Documents SOLAS 74 Reg.II-2/9, IMO MSC.1/Circ.1511/Rev.1
Request 23/10/2025
Expire date 06/11/2030
EC TYPE-EXAMINATION (MODULE B) ENG
Vuoto Querysave
Enrico Cabella S

EC TYPE EXAMINATION (MODULE B)
CERTIFICATE No. MED491525CS

This is to certify that RINA Services S.p.A. (Notified Body No. 0474) did undertake the relevant type approval procedures for the equipment identified below, which was found to be in compliance with the Fire Protection requirements of Marine Equipment Directive (MED) 2014/90/EU, including the requirements and testing standards of Regulation (EU) 2025/1533.
MED Item Nº MED/3.16
USCG Category Nº 164.136
Description Fire doors
Type SSF-A60
Applicant CARETTA INTERIORS AE
THESI MAURI ORA, INDUSTRIAL AREA OF ASPROPYRGOS,19300 ATHENS,GREECE
Testing standards IMO Res. MSC.307(88)-(2010 FTP  Code), as amended.,IMO MSC.1/Circ. 1319
Reference standards SOLAS 74 Reg.II-2/9, IMO MSC.1/Circ.1511/Rev.1
Issued in Genoa on
This Certificate is valid until
November 7, 2025
November 6, 2030
This Certificate consists of this sheet plus an attachment

________________________________________
Enrico Cabella
RINA Services S.p.A.
**** NOTICE: This is NOT an official certificate ****

ATTACHMENT TO
CERTIFICATE No.  MED491525CS
Page 1 of 2

Product description

Single leaf sliding door whose maximum clear opening size is 2383 mm (W) and 2707 mm (H). The leaf, having maximum dimensions of 2497 mm in width and 2719 mm in height, is made of one single panel of a composite material. The panel is composed of three skins of material named NEPTUNE BOARD, 2 mm thick each and having density of 1200 kg/m3 and, in between, two layers of mineral wool (certified non combustible in conformity to the requirements of the IMO FTP Code) 20 mm thick and having density of 160 kg/m3. Vertical stiffeners made of NEPTUNE BOARD are fitted, between the two skins, every 100 mm. The composite panel edge is contained within two U shaped steel profiles having dimensions 40x42x40x1.25 mm and 30x48x30x1 mm. The edges of the leaf are fitted with intumescent strips type KERAFIX FLEXPAN 200 having dimensions of 15x1.5 mm. The steel sliding guide is 25 mm wide and 24 mm deep with a thickness of 1.4 mm. The sliding guide is supported by four steel brackets 6 mm thick and insulated with 2.5 mm of NEPTUNE BOARD on all the surface; it is fixed to the bulkhead by means of four M8x40 bolts. The door may be equipped with a self closing hose port. The door may be installed on aluminium or steel A60 bulkhead.
Field of application
Fire resistant A-60 Class single leaf sliding door with the fire hazard on both sides in compliance with IMO MSC.1/Circ. 1319 dated 11 June 2009. In this case the dimensions relevant to the height and width of the door may be increased of 15% provided that the surface area is not increased of more than 10%.

The surfaces of this division may be fitted with products having low flame spread characteristics, installed as described in the relevant type approval certificates and satisfying the requirements of SOLAS 74 Reg. II-2 as applicable.

In case of doors in compliance to the "Agreement between the European Community and the United States of America", the present certificate is valid at the following conditions:
- maximum door size tested;
- door used with a fire tested frame design.
Reference documents
PANMERC ENTERPRISES LTD drawing No. SSF-60-120 Rev. B dated 17 February 2015 approved on 30 October 2015 with endorsement No. LABS-1153.
Tests carried out
Test as per RINA Test Laboratory reports No. 2014CS013398/2 and 2014CS013398/3 issued on 30 October 2015 according to IMO 2010 FTP Code Part 3.




ATTACHMENT TO
CERTIFICATE No. MED491525CS
Pages 2 of 2
The mark of conformity may only be affixed to the above type approved equipment and a Manufacturer's Declaration of Conformity issued when the production control phase module (D, E or F) of Annex II of the Directive is fully complied with a written inspection agreement with a Notified Body
XXXX/YY
"WHEELMARK FORMAT"

XXXX
Notified Body number undertaking surveillance module
YY
Last two digits of year mark affixed
     
______________________________________________
General conditions for the approval
a) The initial conditions verified by RINA at the time of the approval are to be maintained
b) Any changes to the initial conditions are to be promptly communicated to RINA, which reserves the right to repeat the relevant assessment
c) This certificate will no be valid if the manufacturer makes any changes or modifications to the approved equipment, which have not been notified to, and agreed with RINA
d) RINA personnel are to be allowed to witness during the performances of activities, upon their request
e) The activities are to be carried out in compliance with the RINA Rules and/or other applicable Rules

f) Should the specified regulations or standards be amended during the validity of this certificate, the product is to be reapproved prior to it being placed on board vessels to which the amended regulations or standards apply. 


__________________________________________
Enrico Cabella