MAC045724XPENGB- -  -  N- G7200 -N- S- S- -15/04/2024- Prodotti Elettrici- - SN- N- Jaroslaw Kondracki- N-  - 404,745Jaroslaw KondrackiBbisProdotti ElettriciNumero Pratica,NumDich,Norma,NumBusta,Richiesta,Validità- MAC045724XP- N-Apr 14, 2029404745
 
Form
  Prodotti Elettrici(TO)
MAC045724XP
Certification N. MAC045724XP - (ENG)
Certificate date 15/04/2024
Type Impianti di Automazione
Product Multigas Monitoring System

Model or Denomin.
Items
G7200
Applicant Green Instruments A/S
Place of requester Erhvervsparken 29  % DK- 9700 Brønderslev  % DENMARK
Tel. N.,Fax, Email +45 9645 4500, +45 9645 4501, lmt@greninstruments.com
Standards Rules for the Classification of Ships - Part C - Machinery, Systems and fire protection - Ch.3, Sect.6, Tab.1.
Expire date 14/04/2029
Head Office RINA Poland Plan Approval Centre
Interrut.senza Dettaglio ENG
Vuoto Querysave
S
TYPE APPROVAL CERTIFICATE
No. MAC045724XP
This is to certify that the product below is found to be in compliance with the applicable requirement of the RINA type approval system.

Description Multigas Monitoring System
Type G7200
Applicant Green Instruments A/S
Erhvervsparken 29
DK- 9700 Brønderslev
DENMARK
Reference standards IACS UR E10 Rev 8 corr.1,MEPC.340(77),NTC2008 Appendix 3,Rules for the Classification of Ships - Part C - Machinery, Systems and fire protection - Ch.3, Sect.6, Tab.1.
  

 
 
   .   This Certificate is valid until April 14, 2029
_________________________________
RINA Services S.p.A.
Jaroslaw Kondracki
This certificate consists of this page and 1 enclosure.
**** NOTICE: This is NOT an official certificate ****

TYPE APPROVAL CERTIFICATE
No. MAC045724XP
Enclosure - Page 1 of 3
G7200
Product Description:

This system is a continuous gas monitoring system. The modular design of the system makes it possible to monitor different gases according to customer specification. It can monitor the SO2 and CO2 concentrations in exhaust gases. It provides an accurate measurement of SO2 in ppm, CO2 in percent as well as presents the SO2/CO2 ratio. The gas analyzer is based on both non-dispersive infrared (NDIR) principle and non-dispersive Ultraviolet (NDUV) principle. These principles makes it possible to detect a wide range of gasses among others SO2, CO2, NO2, NO, CH4, CO, HC, N2O and H20. The system includes heated probe(s) and heated hose(s) to maintain the extractive exhaust gas sample at a sufficient temperature to avoid condensed water and loss of SO2.


Technical Data:
G7200 Multigas Monitoring System
Type
G7200
Function
Monitoring of CO2, SO2, NO2, NO, CH4, CO, N2O, HC, H2O
and other relevant gasses.
Equipment including
Analyzer modules, gas cooler, gas pump (s), condensate
pump(s), gas filtration system, flow transmitter, solenoid
valves, air filter regulator and oil/particle separator, air dryer,
HMI, PLC.
Number of Gas Analyzer Modules
1-3 depending on configuration
Power Supply
230 VAC – 50/60 Hz
Power Consumption
16 A - 40 A dependent on system configuration – refer to the
electrical drawings of each system
External Communication
Modbus TCP/IP (RJ45).
Optional Modbus RTU
Air supply quality
ISO 8573-1 Class 3
Free from traces of measured gasses.
Sample flow
0.33 – 1.67 l/min.
Default 0,5L/min.
Max ambient temperature
Class A
From 5°C to 45 °C
Humidity
RH up to 96% at all relevant temperatures
Vibration
Class A
EMC
Class A
Material/Enclosure Class
Painted mild steel RAL 7035
IP54
Dimensions/Weight
1200 x 800 x 300 mm (H x W x D)
Approx. 118 kg depending on configuration
Optional Modules
IoT module
Establish a remote connection link between system and user
Communication Converter Module
Converts bus communication to other standard bus
communication protocols
Ethernet Switch
Used to connect optional modules
TYPE APPROVAL CERTIFICATE
No. MAC045724XP
Enclosure Page 2 of 3
G7200


Analyzer Modules:

Type G7010
Gas Analyzer Measuring principle
NDIR
Measuring Gasses and typical Ranges
CO2: 0 – 10 %
SO2: 0 – 200 ppm
Other ranges upon request
Accuracy/Linearity
≤ ±2 % of reading or
≤ 0.3 % of full scale whichever is larger (except zero)
Precision/Repeatability
≤ ±1 % of full scale above 100 ppm or
≤ ±2 % of full scale below 100 ppm
Noise
≤ ±2 % of full scale
Zero drift
< ±2 % of full scale
Span drift
< ±2 % of full scale
Calibration
Zero Calibration: Automatic using compressed air
Span Calibration: Automatic using inbuilt cuvette which hold
span gas and also possibility to connect mixed test gases for
verification

Type G7210
Gas Analyzer Measuring Principle
NDIR
Measuring Gasses and typical Ranges
Gas Component
Full range
Default range
NO CH4 H2O
CO2 CO N2O
HC
0 – 5000 ppm
0 – 100 %
0 – 5%
0 – 100 %
0 – 100 %
0 – 100 %
0 – 100 %
0 – 1000 ppm
0 – 5000 ppm
0 – 20000 ppm
0 – 20 %
0 – 5000 ppm
0 – 2000 ppm
0 – 5000 ppm
Note: Combination of gasses and ranges are hardware
dependent. Each module can be configured for maximum 4
individual gasses. Kindly contact us for specific requirements.
Accuracy/Linearity
≤ ±2 % of reading or
<= 0.3 % of full scale whichever is larger (except zero)
Precision/Repeatability
≤ ±1 % of full scale above 100 ppm or
≤ ±2 % of full scale below 100 ppm
Noise
≤ ±2 % of full scale
Zero drift
< ±2 % of full scale
Span drift
< ±2 % of full scale
Calibration
Zero Calibration: Automatic using compressed air
Span Calibration: Manually by connecting mixed test gases for
verification
Compensations
Fully temperature and pressure compensated


TYPE APPROVAL CERTIFICATE
No. MAC045724XP
Enclosure Page 3 of 3
G7200
Type G7230
Gas Analyzer Measuring Principle
NDUV + NDIR
Measuring Gasses and typical
Ranges
Gas
Component
Full range
Default range
NO CH4
H2O CO2 CO N2O
HC SO2 NO2
0 – 5000 ppm
0 – 100 %
0 – 5%
0 – 100 %
0 – 100 %
0 – 100 %
0 – 100 %
0 – 10 %
0 – 5000 ppm
0 – 1000 ppm
0 – 5000 ppm
0 – 20000 ppm
0 – 20 %
0 – 5000 ppm
0 – 2000 ppm
0 – 5000 ppm
0 – 300 ppm
0 – 100 ppm
Accuracy/Linearity
≤ ±2 % of reading or
<= 0.3 % of full scale whichever is larger (except zero)
Precision/Repeatability
≤ ±1 % of full scale above 100 ppm or
≤ ±2 % of full scale below 100 ppm
Noise
≤ ±2 % of full scale
Zero drift
< ±2 % of full scale
Span drift
< ±2 % of full scale
Calibration
Zero Calibration: Automatic using compressed air
Span Calibration: Manually by connecting mixed test gases for
verification
Compensations
Fully temperature and pressure compensated

Reference Documents:

P&I & Arrangement & Installation Drawings + System Description filed under RINA dwg no. PLMC-10889
Components + Electrical Drawings + IP Rating Assessment + SQAP filed under RINA dwg no. PLMC-10888
Test Reports + Control Plan + User Manual + Certificates filed under RINA dwg no. PLMC-10890

Application Fields:

The G7200 Multigas Monitoring System may be used on board ships and other units classed by the RINA for exhaust monitoring as well as other applications where continuous monitoring of gasses is relevant. It can be installed as CEMS on SO2 scrubbers according to MEPC.340(77). The system can also be applied as a generic gas monitor for various gasses. For these applications the mentioned relevant sections of NTC 2008, appendix 3 have been demonstrated.

Acceptance Condition:

Correct configuration and set up for each delivery to be tested during commissioning after installation.


The G7200 Multi Gas Monitoring System shall be installed, maintained and operated in compliance with the User Manual.

Remarks:

This Certificate has replaced the previously issued Certificate No. MAC100123XP.


RINA Poland Plan Approval Centre April 15, 2024