| Round pneumatic fire dumper fixed to the coaming, welded to a deck or to a bulkhead, by a flange with M12 mm diameter steel bolts and 5 mm thick ceramic fiber was padded. The fire dumper frame is composed of 10 mm thick steel plate whereas the blades, having width of 43 mm, are composed of an hollow profile made by a carbon steel sheet on both sides, 1.5 mm tick. The blades are filled with 40 mm of a polycrystalline wool, named DJS, with a density of 120 kg/m3. The dumper is fitted with a set of pneumatic actuator A-125SR produced by WUXI ST.HANS CONTROLS CO., LTD; the coaming, the damper (including the actuator) are insulated with two layers of ceramic fiber having density of 170 kg/m3 and thickness of 20 mm, (certified non-combustible in compliance with IMO FTP Code). The ceramic fiber, fixed by means of steel pins and washers, is applied on the coaming, for a minimum length of 445 mm. Field of application Fire resistant A-60 Class fire dampers fitted on decks and bulkheads as per the following tables:
DECK |
Item | Max Dim. mm | Max
Vent. Size
mm | Frame -
Flange thick mm | Blade height
mm | Blade Composition
mm | Actuator
Type |
CF II-Q-Y/D | D: 1720 | D: 1600 | 10 - 5 mm | 235 | 1.5+40+1.5 | Pneumatic |
BULKHEAD |
Item | Max Dim. mm | Max
Vent. Size
mm | Frame -
Flange thick mm | Blade height
mm | Blade Composition
mm | Actuator
Type |
CF II-Q-Y/D | D: 1720 | D: 1600 | 10 - 5 mm | 235 | 1.5+40+1.5 | Pneumatic |
Reference documents Drawings enclosed to FEFTC, Far East Fire Testing Centre, Report No. FT18200 dated 18 September 2018, Report No. FT18201 dated 18 September 2018.Tests carried out Tests as per FEFTC, Far East Fire Testing Centre, Report No. FT18200 dated 18 September 2018, Report No. FT18201 dated 18 September 2018 according to IMO 2010 FTP Code Part. 3 - Annex 1. |