MED372726CS!001ENGF- -  -  N- S-WTD A60 CONTROL SYSTEM -N- S- S- -04/07/2026- Marine Equipment- - SN- S- - N-  - 1,106,187B2bisMarine EquipmentNumero Pratica,Direttiva,Norma,Schema,Richiesta,Validità,EmailR- MED372726CS/001- N-Jul 3, 20311106187
 
Form
  Marine Equipment(TO)
MED175926GE,MED192126GE
Certification N. MED372726CS/001 - (ENG)
Certificate date 04/07/2026
Type Protezione antincendio
Product Componenti dei sistemi di comando delle porte tagliafuoco
Item Nº MED/3.17
USCG Category N° 164.146

Model or Denomin.
Items
S-WTD A60 CONTROL SYSTEM
Applicant GO-TEC Srl
Place of requester Salita Guardia, 60A  %  16014 Ceranesi (GE)  % ITALY
Tel. N.,Fax, Email 010 2543514; dscarso@go-tec.it
Directive (EU) 2025/1533
Standards IMO Res. MSC.307(88)-(2010 FTP  Code), as amended.
Reference Documents SOLAS 74 Reg.II-2/9, SOLAS 74 Reg.X/3, IMO Res.MSC 97(73)-(2000 HSC Code)7.
Request 19/06/2026
Expire date 03/07/2031
EC TYPE-EXAMINATION (MODULE B) ENG
Vuoto Querysave
Enrico Cabella S

EC TYPE EXAMINATION (MODULE B)
CERTIFICATE No. MED372726CS/001

This is to certify that RINA Services S.p.A. (Notified Body No. 0474) did undertake the relevant type approval procedures for the equipment identified below, which was found to be in compliance with the Fire Protection requirements of Marine Equipment Directive (MED) 2014/90/EU, including the requirements and testing standards of Regulation (EU) 2025/1533.
MED Item Nº MED/3.17
USCG Category Nº 164.146
Description Fire door control systems components
Type S-WTD A60 CONTROL SYSTEM
Applicant GO-TEC Srl
Salita Guardia, 60A,16014 Ceranesi (GE),ITALY
Testing standards IMO Res. MSC.307(88)-(2010 FTP  Code), as amended.
Reference standards SOLAS 74 Reg.II-2/9, SOLAS 74 Reg.X/3, IMO Res.MSC 97(73)-(2000 HSC Code)7.
Issued in Genoa on
This Certificate is valid until
July 4, 2026
July 3, 2031
This Certificate consists of this sheet plus an attachment

________________________________________
Enrico Cabella
RINA Services S.p.A.
**** NOTICE: This is NOT an official certificate ****

ATTACHMENT TO
CERTIFICATE No.  MED372726CS/001
Page 1 of 2

Product description



Fire door control system electrically actuated designed for single leaf sliding door. The movement of the door leaf is possible by means of an electric motor acting on a linear actuator. The electric motor is inside a stainless steel box having a thickness of 1 mm, width 500 mm, height 550 mm, depth 400 mm, insulated with a layer of mineral wool (certified non combustible in conformity to the requirements of the IMO FTP Code) having thickness of 60 mm and density of 100kg/m3. The electronic control devices are inside a stainless steel box having a thickness of 1 mm, width 423 mm, height 2505 mm, depth 326 mm, insulated with a layer of mineral wool (certified non combustible in conformity to the requirements of the IMO FTP Code) having thickness of 60 mm and density of 100kg/m3.
Field of application

Fire door control system for sliding doors having maximum leaf weight of 685 kg.
Reference documents

Go-Tec drawing No. P4449-SWTD-00-00-202 2 - Rev-2 dated 15 Jennuary 2021 approved on 05 July 2021 with endorsement No. LABS-2252 and Go-Tec drawing No. P 4449 E 001 C - Rev-C dated 09 October 2020 filed on 05 July 2021 with endorsement No. LABS-2251.
Tests carried out

Tests as per RINA Test Laboratory Report No. 2020CS01342 issued on 05 July 2021 according to APPENDIX 1 of IMO 2010 FTPC Part 4.




ATTACHMENT TO
CERTIFICATE No. MED372726CS/001
Pages 2 of 2
The mark of conformity may only be affixed to the above type approved equipment and a Manufacturer's Declaration of Conformity issued when the production control phase module (D, E or F) of Annex II of the Directive is fully complied with a written inspection agreement with a Notified Body
XXXX/YY
"WHEELMARK FORMAT"

XXXX
Notified Body number undertaking surveillance module
YY
Last two digits of year mark affixed
     
______________________________________________
General conditions for the approval
a) The initial conditions verified by RINA at the time of the approval are to be maintained
b) Any changes to the initial conditions are to be promptly communicated to RINA, which reserves the right to repeat the relevant assessment
c) This certificate will no be valid if the manufacturer makes any changes or modifications to the approved equipment, which have not been notified to, and agreed with RINA
d) RINA personnel are to be allowed to witness during the performances of activities, upon their request
e) The activities are to be carried out in compliance with the RINA Rules and/or other applicable Rules

f) Should the specified regulations or standards be amended during the validity of this certificate, the product is to be reapproved prior to it being placed on board vessels to which the amended regulations or standards apply. 


__________________________________________
Enrico Cabella
**** NOTICE: This is NOT an official certificate ****