Product description
Transits of electric cables, having maximum diameter of 81 mm, installed in A-Class bulkheads and decks. The transits are composed of a steel frame, having thickness of 10 mm and depth of 60 mm, fillet welded, on both sides, to the bulkhead or deck plate. The transits are filled with EPDM modules and, on the upper part, one module fitted with a screw expander is installed. The interstices between the cables and the modules and between the modules, are lubricated by means of product named WallMax Lubricant. The transits are insulated, on both sides, with two layers of mineral wool type SeaRox SL 620, having, each, thickness of 60 mm and density of 100 kg/m3; the mineral wool panels, having dimensions of 400 mm in width and 600 mm (320 mm for frame type WRF 60) in length, are fixed to the bulkhead or deck plate by means of steel pins and washers welded with pitch ranging from 120 up to 200 mm. The certification is valid also for transit types WRF2, WRFD, WRFR2 and WRFR4 and for type WRFO composed of a three-side frame with the fourth side welded afterwards.
Reference documents
WallMax drawing No. 5500001001 Rev. 00 dated 28 June 2017, No. 5500002001 Rev. 00 dated 1 August 2017 and No. 7010102004 Rev. 00 dated 23 June 2017 approved on 20 September 2017, 22 September 2017 and 16 October 2017 respectively with endorsement Nos. LABS-1535, LABS-1537 and LABS-1556.
Tests carried out
Tests as per RINA Test Laboratory Reports No. 2017CS01761/3 dated 20 September 2017 and No. 2017CS01761/6 dated 22 September 2017 issued according to Appendix 1 of IMO 2010 FTPC Part 3 - A.IV Cable Transits.
|
ATTACHMENT TO
CERTIFICATE Nr. MED013226CS/002
Page 2 of 3 |
Field of application Fire resistant A-60 Class cable transits through bulkheads and decks as per following tables:
WRF TYPE - BULKHEAD
Transit dimensions (mm) | Minimum fill
% | Maximum fill
% | Cables - Maximum diameter (mm) |
140x118 | 0.08 | 33.4 | 50 |
140x298 | 0.03 | 39 | 81 |
WRFR6 - BULKHEAD
Transit dimensions (mm) | Minimum fill
% | Maximum fill
% | Cables - Maximum diameter (mm) |
140x238 | 0.04 | 24.8 | 50 |
140x298 | 0.07 | 23 | 81 |
WRF TYPE - DECK
Transit dimensions (mm) | Minimum fill
% | Maximum fill
% | Cables - Maximum diameter (mm) |
140x118 | 0.08 | 33.4 | 50 |
140x298 | 0.03 | 33.5 | 81 |
WRFR6 TYPE - DECK
Transit dimensions (mm) | Minimum fill
% | Maximum fill
% | Cables - Maximum diameter (mm) |
140x238 | 0.08 | 23 | 50 |
140x298 | 0.07 | 22.5 | 81 |
Additional characteristics WallMax Multiple Cable Penetration Transits – WRF, WRFR6, WRF2, WRFD, WRFR2, WRFR4 and WRFO series are certified also as:
Equipment or Protective System Intended for use in Potentially Explosive Atmospheres in compliance with Directive 2014/34/EU with EU-Type Examination Certificate Number ETL24ATEX0397X issued on 25th September 2024 under the names WRF Ex, WRFR6 Ex, WRF2 Ex, WRFD Ex, WRFR2 Ex, WRFR4 Ex and WRFO Ex;
Increased Safety and Dust ignition Protection by enclosure in compliance with Standard IEC 60079-0:2017, IEC 60079-7:2017 and IEC 60079-31:2022 with Certificate No.: IECEx ITS 24.0016X issued on 25th September 2024 under the names WRF Ex, WRFR6 Ex, WRF2 Ex, WRFD Ex, WRFR2 Ex, WRFR4 Ex and WRFO Ex. |