MED016225CS!001ENGB- -  -  N- B-0 CEILING PANEL -N- S- S- -21/01/2025- Marine Equipment- - SN- S- - N-  - 1,083,701B2bisMarine EquipmentNumero Pratica,Direttiva,Norma,Schema,Richiesta,Validità,EmailR- MED016225CS/001- N-Jan 20, 20301083701
 
Form
  Marine Equipment(TO)
MED016225CS/001
Certification N. MED016225CS/001 - (ENG)
Certificate date 21/01/2025
Type Protezione antincendio
Product 'A' and 'B' Class divisions fire integrity: (b) 'B' Class divisions
Item Nº MED/3.11b
USCG Category N° 164.110

Model or Denomin.
Items
B-0 CEILING PANEL
Applicant MERCAN PANEL URETIM SAN. VE TIC. A.S.
Place of requester ÇERKESLI OSB MAH., IMES BULVARI, No.11 DILOVASI, KOCAELI Kocaeli  % TÜRKIYE
Tel. N.,Fax, Email +90 262 502 0180, +90 262 502 0182, yasinyamac@mercanpanel.com
Directive (EU) 2024/1975
Standards IMO Res. MSC.307(88)-(2010 FTP  Code), as amended.
Reference Documents SOLAS 74 Reg. II-2/3.4,SOLAS 74 Reg. II-2/9,IMO Circ. MSC 1120,IMO Circ. MSC.1 1581
Request 17/12/2024
Expire date 20/01/2030
EC TYPE-EXAMINATION (MODULE B) ENG
Vuoto Querysave
Enrico Cabella S

EC TYPE EXAMINATION (MODULE B)
CERTIFICATE No. MED016225CS/001

This is to certify that RINA Services S.p.A. (Notified Body No. 0474) did undertake the relevant type approval procedures for the equipment identified below, which was found to be in compliance with the Fire Protection requirements of Marine Equipment Directive (MED) 2014/90/EU, including the requirements and testing standards of Regulation (EU) 2024/1975.
MED Item Nº MED/3.11b
USCG Category Nº 164.110
Description 'A' and 'B' Class divisions fire integrity: (b) 'B' Class divisions
Type B-0 CEILING PANEL
Applicant MERCAN PANEL URETIM SAN. VE TIC. A.S.
ÇERKESLI OSB MAH., IMES BULVARI, No.11 DILOVASI, KOCAELI Kocaeli,TÜRKIYE
Testing standards IMO Res. MSC.307(88)-(2010 FTP  Code), as amended.
Reference standards SOLAS 74 Reg. II-2/3.4; SOLAS 74 Reg. II-2/9; IMO Circ. MSC 1120; IMO Circ. MSC.1 1581
Issued in Genoa on
This Certificate is valid until
January 21, 2025
January 20, 2030
This Certificate consists of this sheet plus an attachment

________________________________________
Enrico Cabella
RINA Services S.p.A.
**** NOTICE: This is NOT an official certificate ****

ATTACHMENT TO
CERTIFICATE No.  MED016225CS/001
Page 1 of 2

Product description



Ceiling composed of panels having maximum width of 300 mm, installed at 400 mm from the deck. The panels are composed, moving from the exposed side, by a steel sheet, 0.6 mm thick and a layer of mineral wool, lean on it, type Izocam Marine Firebatts 45 having thickness 25 mm and density of 45 kg/m3. The joints between ceiling panels are carried out by bending of the longitudinal edge. The ceiling is connected longitudinally to the bulkhead using “L” steel profile 40x40x1.2 mm screwed on it with pitch of maximum 200 mm and a “U” steel profile 20x25x25 mm and thick 0.6 mm fixed to up mentioned profile by steel rivet 3x8 mm installed with pitch of 250 mm. That rivet keeps in position a “Z” steel profile 25x25x0.6 mm. The ceiling is transversal connected to the bulkhead by “L” steel profile 50x75 and thick 1.2 mm with one row of “V” clip each 300 mm. The transversal joint between the panels is carried out by a continuos steel profile “M-19” 10x115x10 mm and thick 1.2 mm with two rows of “V” clip each 300mm. With a pitch of 1250 mm is installed a continuos transversal stiffeners carried out by a “U” steel profile 33x35x33 mm and thick 1.2 mm with one row of “V” clip of 300 mm. All the transversal stiffeners are connected to the deck by suspension system “M-60” carried out by treated bar and steel plate each 1250 mm.


Field of application

Fire resistant B-0 Class ceiling with fire hazard on side fitted with the steel sheets having thickness of 0.6 mm.


Reference documents

Mercan Panel drawing No. MRN-CP-C1 rev. 1 dated 07 March 2024 enclosed on Test Report N. RFTR24045-REV1 issued on 06/11/2024; Mercan Panel drawing No. MRN-CP-C1 rev.0 dated 20/01/2025 identify by N0. 2025CS01162/1 attachment No. 1 and attachment Mercan Panel drawing No. MRN-CP-C1 rev.1 dated 15/01/2025 identified by N0. 2025CS01162/1 attachment No. 2.


Tests carried out

Tests as per Efectis Test Laboratory report No. RFTR24045 REV1 issued on 06/11/2024 according to IMO 2010 FTP Code.




ATTACHMENT TO
CERTIFICATE No. MED016225CS/001
Pages 2 of 2
The mark of conformity may only be affixed to the above type approved equipment and a Manufacturer's Declaration of Conformity issued when the production control phase module (D, E or F) of Annex II of the Directive is fully complied with a written inspection agreement with a Notified Body
XXXX/YY
"WHEELMARK FORMAT"

XXXX
Notified Body number undertaking surveillance module
YY
Last two digits of year mark affixed
     
______________________________________________
General conditions for the approval
a) The initial conditions verified by RINA at the time of the approval are to be maintained
b) Any changes to the initial conditions are to be promptly communicated to RINA, which reserves the right to repeat the relevant assessment
c) This certificate will no be valid if the manufacturer makes any changes or modifications to the approved equipment, which have not been notified to, and agreed with RINA
d) RINA personnel are to be allowed to witness during the performances of activities, upon their request
e) The activities are to be carried out in compliance with the RINA Rules and/or other applicable Rules

f) Should the specified regulations or standards be amended during the validity of this certificate, the product is to be reapproved prior to it being placed on board vessels to which the amended regulations or standards apply. 


__________________________________________
Enrico Cabella
**** NOTICE: This is NOT an official certificate ****