ELE007523XGENGB- -  -  N- VEGAWELL 52,VEGABOX 02 -N- S- S- -08/02/2023- Prodotti Elettrici- - SN- N- Giuseppe Russo- N-  - 514,475Giuseppe RussoBbisProdotti ElettriciNumero Pratica,NumDich,Norma,NumBusta,Richiesta,Validità- ELE007523XG- N-Feb 7, 2028514475
 
Form
  Prodotti Elettrici(TO)
ELE007523XG
Certification N. ELE007523XG - (ENG)
Certificate date 08/02/2023
Type Impianti di Automazione
Product Trasmettitori di pressione

Model or Denomin.
Items
VEGAWELL 52,VEGABOX 02
Applicant VEGA GRIESHABER KG
Place of requester Am Hohenstein 113,% D-77761 Schiltach% GERMANY
Tel. N.,Fax, Email 0041 1 9223232, 0041 1 9223233, ---
Standards Rules for the classification of ships.- Part C - Machinery, systems and fire protection. - Ch.3, Sect. 6, Table 1.
Expire date 07/02/2028
Head Office HAMBURG
Interrut.senza Dettaglio ENG
Vuoto Querysave
S
TYPE APPROVAL CERTIFICATE
No. ELE007523XG
This is to certify that the product below is found to be in compliance with the applicable requirement of the RINA type approval system.

Description Pressure transmitters
Type VEGAWELL 52
VEGABOX 02

Applicant VEGA GRIESHABER KG
Am Hohenstein 113,
D-77761 Schiltach
GERMANY
Reference standards Rules for the classification of ships.- Part C - Machinery, systems and fire protection. - Ch.3, Sect. 6, Table 1.
  

 
 
   .   This Certificate is valid until February 7, 2028
_________________________________
RINA Services S.p.A.
Giuseppe Russo
This certificate consists of this page and 1 enclosure
**** NOTICE: This is NOT an official certificate ****

TYPE APPROVAL CERTIFICATE
No. ELE007523XG
Enclosure - Page 1 of 2
VEGAWELL 52,VEGABOX 02
Product description:
VEGAWELL 51 and 52 suspension cable pressure transmitters with integrated temperature sensor for level and gauge measurement. The sensor element is a dry ceramic-capacitive measuring cell.
The hydrostatic pressure causes a capacitance change in the measuring cell, via the ceramic diaphragm.
VEGABOX 02 Connection box: Breather housing for pressure transmitters with connection cable with integrated capillary tube, with or without temperature transmitter for PT100

WL 52 - a M bc d e f g h i j k
BOX 02 - a M b c d
a=Approval (note 1)
a=Approval (note 1)

X without Ex - Approval

X without Ex - Approval

A...Z in combination with Ex Approval for
use in hazardous atmospheres


A...Z in combination with Ex
Approval for use in hazardous atmospheres
bc=Process fittings
AA/ A1...ZZ / Z9 without straining clamp, screw connection,
housing with cable locking

b=Function
A Equalisation
C Equalisation and temperature transmitter 4...20mA / HART
d=Material Suspension cable
B FEP
D PUR

c=Protection cap
X with
W without
e=Total lenght
T customer specific

d=Label
X without
f=Transmitter Material / Diameter
A...Z Stainless Steel, PVDF,Titan;


V made of Stainless Steel
F of foil, laser marking
g=Measuring cell seal
1...9/A...Z FKM, FFKM, EPDM



h=Pressure / measuring range
A...Z gauge pressure max. 25 bar
1...9 absolute pressure max. 25 bar
(VEGAWELL 52 up to 60 bar max)



i=Electronics
D 4...20mA / HART +Pt100, 4 wire
C 4...20mA /2 wire



j =Accuracy class:
1 0.20%; 2 0.10%



k =Transmitter Option:
w without,
v with impact protection



Note 1: For use in hazardous area the requirement / instruction of the relevant safety certificates must be taken into consideration.

Safety references:
VEGAWELL 51/52 type VEGAWELL WL51/52.A********C/D*
Certificate: TUV 06 ATEX 553449 X 3. Supplement
Marking: II 1 G or II 2 G Ex ia IIC T6 Ga, Gb

VEGABOX 02 BOX 02.C_***
Certificate: TUV 07 ATEX 553685 X
Marking: II 1 G or II 2 G Ex ia IIC T6 Ga, Gb







TYPE APPROVAL CERTIFICATE
No. ELE007523XG
Enclosure - Page 2 of 2
VEGAWELL 52
VEGABOX 02

Additional Place of Manufacture:

VEGA Americas, Inc.
3877 Mason Research Parkway
Mason, OH 45036
USA

Documents:
Operating instructions: - 35401-EN-180523; 35402-EN-180523; 36785-EN-180523; 42240-EN-131108
Safety Instructions: - VEGAWELL WL51 /52.A ********C/D* and VEGABOX 02 BOX 02.C_***.


Test reports:
Paconsult: - 07-1587 dated 24/05/2007; 07-1650 dated 06/08/2007;
Hanse Control: - 07-L-00339-01 / 02 dated 20-23/04/2007; 07-L-00954-01 dated 21/07/2007;
- 07-L-00956-01 dated 26/07/2007; 08-L-00256-01 dated 27/02/2008; 2101-0046101R01A,EMC dated 24/03/2021; 2101-0046101R02A,EMC dated 24/03/2021; 2101-0046101R03A,EMC dated 24/03/2021; 2101-0046101R04A,EMC dated 24/03/2021;
VEGA Grieshaber: - 2-03_WELL51-F1_1 dated 27/02/08; 1-03-WELL52-PVDF_F1_1 dated 10/12/07;
- 1-4-WELL-PVDF_F1_1 dated 10/12/07


Remarks:
This certificate annuls and replaces the previous one n° ELE135718XG.

HAMBURG February 8, 2023
**** NOTICE: This is NOT an official certificate ****