| Double-leaf hinged glass door with clear passage dimensions of 1800x2200 mm (WxH) and door leaf dimensions of 1245x2220 mm and 645x2220 mm (WxH). PYROBELITE 12 glass is composed, starting from the side opposite the hinges (the side exposed to fire), of three 3 mm thick tempered float glass panes and two 1.5 mm thick intumescent interlayers, for a total thickness of 12 mm. The lower part of the glass door frame consists of FOSTER code 735.850 carbon steel profiles with a thickness of 65x50 mm; the vertical uprights and upper part feature a FOSTER code 735.800 profile measuring 65x70 mm. The doors are equipped with FOSTER code 901.227 glass stops, screwed in place using FOSTER code 906.577 self-drilling carbon steel bolts. The glass is held in place by a 15x4 mm FOSTER code 948.004 glass gasket. There are two FOSTER seals (code 905.307) between the door and the frame, and each FOSTER profile has a FOSTER intumescent seal (code 948.000). The door frame consists of a FOSTER profile, code 735.800, measuring 65x70 mm, equipped on each vertical upright with 5 carbon steel plates measuring 24x100 mm and 2 mm thick, spaced at intervals varying between 340 mm and 457 mm. in the upper part there are 4 carbon steel plates measuring 24x100 mm and 2 mm thick, spaced at 580 mm intervals and fixed with 4.2x70 mm carbon steel screws to 25x53x25 mm carbon steel C-profiles and 1.5 mm thick positioned on the cut of the class B-15 bulkhead (MED1850112 of 12/06/2018). The doors are equipped with 3 hinges each and, on the main door, a central handle on both sides. The secondary door is equipped with two manual carbon steel Stambecco type 380 latches. Field of application Fire resistant B-15 Class single leaf hinged door. The door is also in compliance with IMO MSC.1/Circ. 1319 dated 11 June 2009. In this case the dimensions relevant to the height and width of the door may be increased of 15% provided that the surface area is not increased of more than 10%.
In case of doors in compliance to the "Agreement between the EEA EFTA States and the United States of America", the present certificate is valid at the following conditions:
- maximum door size tested;
- door used with a fire tested frame design.Reference documents S.I.N. Service drawing No. "B15GL2AAS" Rev. 04 dated 04/06/2025 enclosed on Test Report N.2025CS012874 dated 01/08/2025 .
Tests carried out Tests as per RINA Test Laboratory Report No. 2025CS012874 dated 01/08/2025 issued according to IMO 2010 FTP Code Part 3. |