Product Description
● Sound Reception System Model HSR-1400 consists of:
1) SRM-141 Main Control and Display Unit
- power supply: AC110/220V & DC24V with power fail signal (dry contact output)
- frequency range: 70 ~ 820Hz (wide mode: 70 ~ 2100 Hz)
- visual indicator: 8(eight) LED for direction indication
- self testing function, built-in loudspeaker with volume control
- disable function: mute circuit (dry contact input) while ship’s horn or whistle is sounded
- data communication interface: RS232 or RS422
2) SRR-142 Microphone Unit
- single unit with 4(four) microphones
# The HSR-1400 Sound Reception System does not issue alerts, hence testing according to IEC 62923-1 and IEC 62923-2 is deemed as not being applicable.
Reference Documentation
● Operation & Installation Manual: Hanshin Document no. HS-HSR140-160620 dated 20 June, 2016
● Drawing: Hanshin Document no. SRS-100C-101 Rev. 1.1f dated 22/06/2015, no. SRS-100C-201 Rev. 1.0c dated 02 July, 2015, no. SRS-100C-301 Rev. 1.0d dated 27 August, 2013, no. SRS-100C-401 Rev. 1.1b dated 08 June, 2015, no.SRS-100C-501 Rev. 1.0c dated 07 September, 2015 and no. SRS-200C-011 Rev. 1.1c dated 01 September, 2015
● System Diagram: Hanshin Document no. SRS-100M-191 Rev. 1.0a dated 29 June, 2016
● Software Flowchart: Hanshin Document no. SRS-100M-201 Rev. 1.0a dated 29 June, 2016
● Asbestos-free Declaration: Hanshin Declaration letter dated 21 June, 2016
● Performance Test according: KCL Test Report no. CT16-021084 dated 11 April, 2016
● EMC Test: ONETECH Test Report no. R166R-D058 dated 16 June, 2016
● ENV and other Test: ONETECH Test Report no. R166R-D016 dated 16 June, 2016
- above-mentioned documents are filed with RINA Appr no. PUEL-15278/9 dated 22 June, 2026
● Final Inspection & Function Test witnessed by RINA Surveyor Hanshin Test Report dated 24 June, 2021, filed with RINA Appr. no. PUEL-15280.
● Gap Analysis Report dated 3 June, 2026, filed with RINA Appr no. PUEL-15240.