ELE068422XGENGB- -  -  N- FES - Electrical discharge panel -N- S- S- -17/05/2022- Prodotti Elettrici- - SN- N- Giuseppe Russo- N-  - 206,287Giuseppe RussoBbisProdotti ElettriciNumero Pratica,NumDich,Norma,NumBusta,Richiesta,Validità- ELE068422XG- N-May 16, 2027206287
 
Form
  Prodotti Elettrici(TO)
ELE068422XG
Certification N. ELE068422XG - (ENG)
Certificate date 17/05/2022
Type Impianti di Automazione
Product Sistema di comando, e monitoraggio

Model or Denomin.
Items
FES - Electrical discharge panel
Applicant FIREBOY-XINTEX UK Operations Ltd
Place of requester 10 HOLTON ROAD, HOLTON HEATH  %  BH16 6LT Poole  % UNITED KINGDOM
Tel. N.,Fax, Email 00448453899462, 00441202625376, raldous@fireboy-xintex.com
Standards "RINA Rules for the Classification of Ships - Part C, Machinery, Systems and Fire Protection - Chapter 3, Section 6 , table 1"
Expire date 16/05/2027
Head Office Hamburg
Interrut.senza Dettaglio ENG
Vuoto Querysave
S
TYPE APPROVAL CERTIFICATE
No. ELE068422XG
This is to certify that the product below is found to be in compliance with the applicable requirement of the RINA type approval system.

Description Monitoring and control system
Type FES - Electrical discharge panel
Applicant FIREBOY-XINTEX UK Operations Ltd
10 HOLTON ROAD, HOLTON HEATH
BH16 6LT Poole
UNITED KINGDOM
Reference standards "RINA Rules for the Classification of Ships - Part C, Machinery, Systems and Fire Protection - Chapter 3, Section 6 , table 1"
  

 
 
   .   This Certificate is valid until May 16, 2027
_________________________________
RINA Services S.p.A.
Giuseppe Russo
This certificate consists of this page and 1 enclosure
**** NOTICE: This is NOT an official certificate ****

TYPE APPROVAL CERTIFICATE
No. ELE068422XG
Enclosure - Page 1 of 1
FES - Electrical discharge panel
Product Description:
The FES discharge panel is a electric release panel with integrated timer for release with optional engine shut down switches.The FES discharge panel is approved for the use in FES extinguishing system using HFC-227ea or FK 5-1-12. The integrated pressure monitoring will trigger an alarm in case of low pressure.

Technical data:
Power supply: 2x 24V DC (monitored)
Output:
FES-001PEv2-xx
2 x NC Power supply failure
1 x NC Main Cylinder Pressure Monitor
1 x NC Main Solenoid Connector Monitor
1 x NC Shutdown Switch(optional) 24V
1 x Low Pressure Alarm 24V max 500mA
1 x Pre-Discharge Alarm 24V max 500mA
FES-001PEv2-xx
2 x NC Power supply failure
2 x NC Main Cylinder Pressure Monitor
2 x NC Main Solenoid Connector Monitor
1 x NC Shutdown Switch(optional) 24V
2 x Low Pressure Alarm 24V max 500mA
2 x Pre-Discharge Alarm 24V max 500mA

Variants:
Part No. Description
FES-001PEv2-xx* Single Electrical Release Panel - STANDARD
FES-001PETv2-xx Single Electrical Release Panel - NO SHUTDOWN
FES-002PEv2-xx* Dual Electrical Release Panel - STANDARD
FES-002PE-MRv2-xx Dual Electrical Release Panel - MAIN & RESERVE
FES-002PE-PS Dual Electrical Release Panel - PORT & STARBOARD
* -xx Optional front layout options

Documents:
Drawings: - FES DischargePanel V2; FES-001PEv2; FES-002PE-MRv2
MS Testing: - TL21125 Issue 0/1 dated 28 Oct. 2021/ 18 Oct. 2021

Remarks:
- EC-Code: 41 / 31
- The EMC requirements for installation on the Bridge and Deck Zones will be fulfilled by the equipment.
- Each particular application and installation is to be specifically approved.
- A Manual Strike Actuator or a Cable Release Actuator is to be mounted acc. to manufacturer instruction.


Hamburg May 17, 2022
**** NOTICE: This is NOT an official certificate ****