Materials/Components
Marine power cables designed according to IEC 60092-353.
Rated voltage: 0,6/1 or 1,8/3 kV
Maximum rated conductor temperature: + 90 oC
Type: LSM-FRHF (1J2XC7Z1-R, 1J2XC7Z1-K EMC), LSM-HF (1XC7Z1-R, 1XC7Z1-K EMC), LSM-FRHF (1J2XC4Z1-R, 1J2XC4Z1-K), LSM-HF (1XC4Z1-R, 1XC4Z1-K)
Marking: PRYSMIAN - AFUMEX MARINE CABLES - TYPE - SIZE - 0, 6/1 or 1, 8/3 kV - IEC 60092-353 - YEAR - metric marking (by ink)
Construction
Conductors: R types: Stranded copper conductor, class 2
K types: Flexible stranded copper conductor, class 5.
Mica Tape: Only for J (FR) typed cables
Core Insulation: HF XLPE
Inner Covering: LSOH filler / LSOH inner covering or tape
Metal Covering: Bare copper wire braiding (only for C4 and C7 typed)
Screen: Electro Magnetic Compatible (EMC) %100 covered copper tape screen (EMC cables only)
Outer Sheath: SHF1
No of Core: 1 to 6 / Cross-sectional area 10 to 300 mm2
Reference documents : Test Report: Türk Prysmian Kablo 20250028 , dated 14.05.2025
Reference Standards: IEC60092-350; IEC60092-353; IEC60092-360; IEC 60228; IEC 60332-3-22 cat A; IEC 60332-1-2; IEC 61034-1/2; IEC 60754-1/2; IEC 60331-11; IEC 60331-21; RINA Rules for the Classification of Ships; RINAMIL; RINA Rules for FPV; RINAMIL for FREMM; RINA Rules for Floating Offshore Units and MODU.