Materials/Components
Halogen free instrumentation and communication cable with XLPE insulation, copper wire braiding and thermoplastic outer sheath.
Rated voltage: 150 /250 V
Maximum rated conductor temperature: + 90 oC
Type: LJST-HF (03XPC4Z1-R, 03XPC4Z1-R PIMF), LJST-FRHF (03J2XPC4Z1-R,03J2XPC4Z1-R PIMF), LJT-HF (03XPZ1-R, 03XPATZ1-R, 03XPATZ1-R PIMF), LJT-FRHF (03J2XPATZ1-R, 03J2XPATZ1-R PIMF)
Marking: PRYSMIAN -AFUMEX MARINE CABLES - TYPE -SIZE - - 250 V - IEC 60092-376 - IEC 60332-3/A + YEAR + metric marking (by ink)
(For FR cables) PRYSMIAN -AFUMEX MARINE CABLES - TYPE -SIZE - - 250 V - IEC 60092-376 - IEC 60332-3/A - IEC 60331 + YEAR + metric marking (by ink)
Construction
Conductors: R types: Stranded copper conductor, class 2
Mica Tape: Only for J (FR) typed cables
Core Insulation: HF XLPE
Pairs: 2 cores twisting (individual screen-laminated electrostatic screen for PIMF typed only)
Metal Covering: Bare copper wire braiding (only for C4 typed)
Screen: Laminated electrostatic screening tape (for PAT typed only)
Outer Sheath: SHF1
No of Pairs: 1P to 37P / Cross-sectional area 0,5 to 1.5 mm2
Reference documents : Test Report: Türk Prysmian Kablo 20250030, dated 14.05.2025
Reference Standards: IEC60092-350; IEC60092-353; IEC60092-360; IEC 60228; IEC 60332-3-22 cat A; IEC 60332-1-2; IEC 61034-1/2; IEC 60754-1/2; IEC 60331-11; IEC 60331-21; RINA Rules for the Classification of Ships; RINAMIL; RINA Rules for FPV; RINAMIL for FREMM; RINA Rules for Floating Offshore Units and MODU.