The pipe penetration is carried out by a steel cylinder min. Ø280 mm max. Ø1020 mm , height 165 mm and thickness 5 mm welded on the unexposed side of the deck. A steel pipe min. DN50, thickness 3.18 mm, max. DN800, thickness 5 mm, pass inside the cylinder. On the pipe is welded a steel flange having “L”, Ø external min. 420 mm, max. 1160 mm, height 40 mm and thickness 5 mm. The gap between flange and penetration cylinder is 25 mm . Outside the penetration, on the unexposed side, a steel ring having min. Ø420 mm, max. Ø1160 mm, height 50 mm and thickness 5 mm, is welded on the deck. Inside the penetration on the exposed side, the pipe is insulated for a height of 595 mm from the welded flange on the pipe, by 2 layers of mineral wool having thickness 40 mm and density of 100 kg/m³, named Rockwool PROROX WM 960 with metallic net secured by steel wire. On the exposed side, externally to the up described insulation, for a height of 400 mm starting from the deck, are applied 3 layer of mineral wool thickness 40 mm and density of 100 kg/m³, named Rockwool PROROX WM 960 with metallic net secured by steel wire. On the unexposed side, externally to the cylinder penetration, for a height of 195 mm from the deck, are applied 2 layers of mineral wool having thickness 40 mm and density 100 kg/m³, named Rockwool PROROX WM 960 with metallic net. On the unexposed side, externally to the pipe, for a height of 205 mm from the welded flange, are applied 3 layers of mineral having thickness 40 mm and density 100 kg/m³ named Rockwool PROROX WM 960 with metallic net secured by steel wire. From the flange welded on the pipe and the ring welded on the deck, using inox clamps, are installed a gasket made of HT silicone named BBV Tech srl EVV051501, thickness, thickness 3 mm, density 1300 kg/m³ and one layer of glass fiber cover named rex thermoglas Gewebe 200 - 1300 kg/m².
Field of application
Fire resistant A-30 Class metal pipes penetration through Deck as per below table.
range Ø | min. 50 | max. 800 |
thick min. | 3.18 mm | 5 mm |
Reference documents
BBV-Tech drawing no. 1C-9301 rev. 02 dated 27/02/2024.
Tests carried out
RINA Test Report No. 2024CS01576/1 issued on 20/04/2024 according to IMO 2010 FTP Code. |