MED411524CS!003ENG- -  -  N- EAST-EM/A0 - Bulkhead -N- S- S- -03/06/2025- Marine Equipment- - SN- S- - N-  - 2,327,397B2bisMarine EquipmentNumero Pratica,Direttiva,Norma,Schema,Richiesta,Validità,EmailR- MED411524CS/003- N-Jun 2, 20302327397
 
Form
  Marine Equipment(TO)
Certification N. MED411524CS/003 - (ENG)
Certificate date 03/06/2025
Type Protezione antincendio
Product Penetrations through "A" Class divisions: (a) electric cable transits
Item Nº MED/3.26a
USCG Category N° 164.138

Model or Denomin.
Items
EAST-EM/A0 - Bulkhead
Applicant EAST SEALING TECH (JIANGSU) CO., LTD.
Place of requester SMEs Innovation Park, Nanhuan Road, Fuqiao Town Taicang (Jiangsu)  % CHINA
Tel. N.,Fax, Email ---, ---, ---
Directive (EU) 2024/1975
Standards IMO MSC.1/Circ. 1488,IMO Res. MSC.307(88)-(2010 FTP  Code), as amended.
Reference Documents SOLAS 74 Reg. II-2/9,IMO Res. MSC.1/Circ.1655.
Request 08/07/2024
Expire date 02/06/2030
EC TYPE-EXAMINATION (MODULE B) ENG
Vuoto Querysave
Enrico Cabella S

EC TYPE EXAMINATION (MODULE B)
CERTIFICATE No. MED411524CS/003

This is to certify that RINA Services S.p.A. (Notified Body No. 0474) did undertake the relevant type approval procedures for the equipment identified below, which was found to be in compliance with the Fire Protection requirements of Marine Equipment Directive (MED) 2014/90/EU, including the requirements and testing standards of Regulation (EU) 2024/1975.
MED Item Nº MED/3.26a
USCG Category Nº 164.138
Description Penetrations through "A" Class divisions: (a) electric cable transits
Type EAST-EM/A0 - Bulkhead
Applicant EAST SEALING TECH (JIANGSU) CO., LTD.
SMEs Innovation Park, Nanhuan Road, Fuqiao Town Taicang (Jiangsu),CHINA
Testing standards IMO MSC.1/Circ. 1488,IMO Res. MSC.307(88)-(2010 FTP  Code), as amended.
Reference standards SOLAS 74 Reg. II-2/9; IMO Res. MSC.1/Circ.1655.
Issued in Genoa on
This Certificate is valid until
June 3, 2025
June 2, 2030
This Certificate consists of this sheet plus an attachment

________________________________________
Enrico Cabella
RINA Services S.p.A.
**** NOTICE: This is NOT an official certificate ****

ATTACHMENT TO
CERTIFICATE No.  MED411524CS/003
Page 1 of 3

Product description


EAST-EM/A0 Type Cable Transit (of specification 1050 mm x 606 mm x 60 mm).

The cable frame was rolled and welded by 10 mm thick steel plate, and fixed to the bulkhead opening by electric welding. Cable having size from Ø 5.5 mm to Ø 98 mm , penetrated the transit. The cables occupied is min. 0.055% and max. 35.55% of the cross-sectional area of the transit. The distance between cable and cable frame was > 3.5 mm and the distance between cables was > 5.5 mm. Modules are used as the sealing material in the cable frame. The length of the module layer along the penetration direction was 60 mm. A metal partition plate was used between modules in the cable frame to secure them. Both surface surface of the specimen was naked without insulation material.

EAST-EM/A0 Type Cable Transit (of specification Ø 220 mm x 78 mm in size).

The cable barrel was rolled and welded by 10 mm thick steel plate, and fixed to the bulkhead opening by electric welding. Cable having size from Ø 14.5 mm to Ø 53 mm , penetrated the transit. The cables occupied is min. 0.24% and max. 28.1% of the cross-sectional area of the transit. The distance between cable and cable barrel was > 36 mm and distance between cable was > 12 mm. Modules were used as the sealing material in the cable frame. The length of the module layer along the penetration direction was 78 mm. A metal partition plate was used between modules in each layer. When the cables, fasteners were installed above modules in the cable frame to secure them. Both surface surface of the specimen was naked without insulation material.

EAST-EM/A0 Type Cable Transit (of specification Ø 63 mm x 78 mm in size).

The cable barrel was rolled and welded by 6.5 mm thick steel plate, and fixed to the bulkhead opening by electric welding. Cable having size from Ø 5.5 mm to Ø 28 mm , penetrated the transit. The cables occupied is min. 8.4% and max. 31.35% of the cross-sectional area of the transit. The distance between cable and cable barrel was > 10 mm. Modules were used as the sealing material in the cable frame. The length of the module layer along the penetration direction was 78 mm. A metal partition plate was used between modules in each layer. When the cables, fasteners were installed above modules in the cable frame to secure them. Both surface surface of the specimen was naked without insulation material.

EAST-EM/A0 Type Cable Transit (of specification 80.5 mm x 120 mm x 60 mm).

The cable frame was rolled and welded by 10 mm thick steel plate, and fixed to the bulkhead opening by electric welding. Cable having size from Ø 5.5 mm to Ø 53 mm , penetrated the transit. The cables occupied is min. 0.4% and max. 36.7% of the cross-sectional area of the transit. The distance between cable and cable frame was > 5 mm. Modules are used as the sealing material in the cable frame. The length of the module layer along the penetration direction was 60 mm. A metal partition plate was used between modules in the cable frame to secure them. Both surface surface of the specimen was naked without insulation material.


 



ATTACHMENT TO
CERTIFICATE Nr. MED411524CS/003
Page 2 of 3


Reference documents

Drawings enclosed in Far East Fire Testing Centre Reports No. FT21384 dated 28 December 2021.

Tests carried out
Drawings enclosed in Far East Fire Testing Centre Reports No. FT21384 dated 28 December
2021. issued according to IMO 2010 FTPC Part 3.
Field of application
Fire resistant cable transits through A0 bulkheads.




ATTACHMENT TO
CERTIFICATE No. MED411524CS/003
Pages 3 of 3
The mark of conformity may only be affixed to the above type approved equipment and a Manufacturer's Declaration of Conformity issued when the production control phase module (D, E or F) of Annex II of the Directive is fully complied with a written inspection agreement with a Notified Body
XXXX/YY
"WHEELMARK FORMAT"

XXXX
Notified Body number undertaking surveillance module
YY
Last two digits of year mark affixed
     
______________________________________________
General conditions for the approval
a) The initial conditions verified by RINA at the time of the approval are to be maintained
b) Any changes to the initial conditions are to be promptly communicated to RINA, which reserves the right to repeat the relevant assessment
c) This certificate will no be valid if the manufacturer makes any changes or modifications to the approved equipment, which have not been notified to, and agreed with RINA
d) RINA personnel are to be allowed to witness during the performances of activities, upon their request
e) The activities are to be carried out in compliance with the RINA Rules and/or other applicable Rules

f) Should the specified regulations or standards be amended during the validity of this certificate, the product is to be reapproved prior to it being placed on board vessels to which the amended regulations or standards apply. 


__________________________________________
Enrico Cabella
**** NOTICE: This is NOT an official certificate ****