Bulkhead composed of two carbon steel panels having a maximum width of 1566x3000 mm; the joint between the two panels is achieved by means of two Z-shaped carbon steel profiles, as shown in the drawing, having a thickness of 4 mm, welded to the panels themselves and bolted together by means of M10 stainless steel bolts with a pitch of 310 mm; each panel is composed of two corrugated sheets welded together, having a maximum width of 1050 mm.
The sheet, having a thickness of 2 mm, presents a corrugation with a smaller base 120 mm wide, 39.6 mm high and an angle of 36° with respect to the larger base, with a pitch of 350 mm.
The insulation of the sheet consists of two layers of mineral wool Rockwool type SeaRox SL620 with a density of 100 kg/m³ and a thickness of 40 mm each; having dimensions of 600x1200 mm, positioned vertically with the first layer staggered with respect to the next by 300 to 600 mm.
On the external side of the insulation, for fixing it to the bulkhead, a perforated carbon steel sheet with a thickness of 1.5 mm is provided, with holes of 4 mm diameter and arranged alternately at 60° with a 40% void/solid ratio; fixed by means of: M6 stainless steel threaded studs welded to the sheet, one graphite washer, one stainless steel washer and one M6 stainless steel cap nut, with a pitch of 300x300 mm.
On the joint between the panels, on the non-fire-exposed side, there is an EPDM gasket MG Tecnoforniture type ZGAAD351 having dimensions 35x10 mm. Between the two panels two Promat intumescent seals type Promaseal-PL-SK/G having dimensions 50x1.8 mm are provided, one on each Z-profile; on the coupling between the two Z-profiles, on the non-fire-exposed side, there is a mineral fibre gasket Bifire type paperseal ECO having a width of 20 mm.
On the joint between the panels, on the non-exposed side, a protection cover is provided consisting of a perforated carbon steel sheet having a thickness of 1.5 mm, with holes of 4 mm diameter and arranged alternately at 60° with a 40% void/solid ratio, and dimensions of 89x200x35 mm, insulated with the same insulation package provided for the bulkhead and fixed with one M6 stainless steel screw and washer with a pitch of 300 mm, to the insulation retaining sheet of the panels forming the bulkhead.
Field of application Fire resistant A-60 Class lightweight bulkhead for general application.
The certificate item is not in compliance with the requirement of Fire Test Procedure Code Part 3 regarding:
- the thickness of the bulkhead
- corrugated plate without stiffeners
These characteristics must be taken into account.
Reference documents Sital drawings No. 8048-55-5479-ST-DWG-001 Rev. 00 dated 04/03/2026 enclosed to Test Report No. 2025CS015673/3 issued on 10/03/2026.
Tests carried out Tests as per Rina laboratory test report No. 2025CS015673/3 issued on 10/03/2026 according to IMO 2010 FTP Code Part 3. |