MED112926CSENGF- -  -  N- TFDD-ZA/QA-R/SA -N- S- S- -04/03/2026- Marine Equipment- - SN- S- - N-  - 1,079,863B2bisMarine EquipmentNumero Pratica,Direttiva,Norma,Schema,Richiesta,Validità,EmailR- MED112926CS- N-May 19, 20301079863
 
Form
  Marine Equipment(TO)
MED955025WS/002,MED955025WS/003
Certification N. MED112926CS - (ENG)
Certificate date 04/03/2026
Type Protezione antincendio
Product Sbarramenti antincendio
Item Nº MED/3.22

Model
Items/Sizes
TFDD-ZA/QA-R/SA
Applicant TAIZHOU TIANFU THERMOTECHNICAL EQUIPMENT MANUFACTURE CO., LTD.
Place of requester No.158 Meilan West Road Taizhou (Jiangsu)  % CHINA
Tel. N.,Fax, Email +86 13815966589, ---, 13815966589@139.com
Directive (EU) 2025/1533
Standard IMO Res. MSC.307(88)-(2010 FTP  Code), as amended.
Reference Documents SOLAS 74 Reg. II-2/9,IMO Res. MSC.1/Circ.1655.
Request 28/02/2026
Validity 19/05/2030
EC TYPE-EXAMINATION (MODULE B) ENG
Vuoto Querysave
Enrico Cabella S

EC TYPE EXAMINATION (MODULE B)
CERTIFICATE No. MED112926CS

This is to certify that RINA Services S.p.A. (Notified Body No. 0474) did undertake the relevant type approval procedures for the equipment identified below, which was found to be in compliance with the Fire Protection requirements of Marine Equipment Directive (MED) 2014/90/EU, including the requirements and testing standards of Regulation (EU) 2025/1533.
MED Item Nº MED/3.22
Description Fire dampers
Type TFDD-ZA/QA-R/SA
Applicant TAIZHOU TIANFU THERMOTECHNICAL EQUIPMENT MANUFACTURE CO., LTD.
No.158 Meilan West Road Taizhou (Jiangsu),CHINA
Testing standards IMO Res. MSC.307(88)-(2010 FTP  Code), as amended.
Reference standards SOLAS 74 Reg. II-2/9; IMO Res. MSC.1/Circ.1655.
Issued in Genoa on
This Certificate is valid until
March 4, 2026
May 19, 2030
This Certificate consists of this sheet plus an attachment

________________________________________
Enrico Cabella
RINA Services S.p.A.
**** NOTICE: This is NOT an official certificate ****

ATTACHMENT TO
CERTIFICATE No.  MED112926CS
Page 1 of 3

Product description



Marine pneumatic, manual and motorized fire dampers on bulkhead. Dimensions of fire damper was: Specimen A 1600x1400 mm, Specimen B 800x800 mm and Specimen C 450x600 mm.
Specimen A TFDD-1600x1400-QA-R: this fire damper was equipped, on the outer surface, by a pneumatic actuator type SR85 produced and provided by Wuxi St.Hans Pneumatic Valve Actuator Manufacturing Co.Ltd. The fire damper was fixed to the coaming by thirty-two M8mm steel bolts, and was padded with 20mm of ceramic wool.
Specimen B TFDD-800x800-SA: this fire damper was equipped, on the outer surface, by a manual actuator type DL-CII-3 produced and provided by Ningbo East Spirit of Plumbing Air Conditioning Part Co.,Ltd. The fire damper was fixed to the coaming by eighteen M8mm steel bolts, and was padded with 20mm of ceramic wool.
Specimen C TFDD-450x600-ZA: this fire damper was equipped, on the outer surface, by an motorized actuator type BFN-230 produced and provided by Belimo Actuators (Shangai) Trading Ltd. The fire damper was fixed to the coaming by fifteen M8mm steel bolts, and was padded with 20mm of ceramic wool.
The fire dampers and its operative control were positioned on the exposed side of the bulkhead and was fixed to the coaming and the coaming was fixed to the bulkhead structural core by welding. For each fire dampers the blade was 30 mm thick, of composite structure, which was composed, from the exposed side, of 2 mm steel plate, a layer of ceramic wool and 2 mm steel plate. The insulating material used on fire damper was TG type ceramic wool produced by Zhejiang Province Deqing County Pusen Fireproof Material Co., Ltd. having thickness of 25 mm and density of 170 kg/m3 (certified non-combustible in compliance with IMO FTP Code).

















 



ATTACHMENT TO
CERTIFICATE Nr. MED112926CS
Page 2 of 3




Field of application

Fire resistant A-60 Class fire dampers fitted on bulkhead as per the following table:

item
Maximum
Ventilation
Size
(mm)
Maximum External
Size
(mm)
Penetration
lenght
(mm)
Coaming
Thickness
(mm)
Damper body
(mm)
Distance between
damper and
structural core
(mm)
Actuator
type
TFDD
1600x1400
1676x1476
320
8
8
230
Pneumatic
800x800
1676x1476
320
6
8
230
Manual
450x600
526x676
320
6
6
260
Motorized
Reference documents

Drawings enclosed to FEFTC, Far East Fire Testing Centre, Report No. FT18212 dated 25 September 2018 and Report No. FT18213 dated 25 September 2018.
Tests carried out

Tests as per FEFTC, Far East Fire Testing Centre, Report No. FT18212 dated 25 September 2018 and Report No. FT18213 dated 25 September 2018 according to IMO 2010 FTP Code Part. 3 - Annex 1.




ATTACHMENT TO
CERTIFICATE No. MED112926CS
Pages 3 of 3
The mark of conformity may only be affixed to the above type approved equipment and a Manufacturer's Declaration of Conformity issued when the production control phase module (D, E or F) of Annex II of the Directive is fully complied with a written inspection agreement with a Notified Body
XXXX/YY
"WHEELMARK FORMAT"

XXXX
Notified Body number undertaking surveillance module
YY
Last two digits of year mark affixed
     
______________________________________________
General conditions for the approval
a) The initial conditions verified by RINA at the time of the approval are to be maintained
b) Any changes to the initial conditions are to be promptly communicated to RINA, which reserves the right to repeat the relevant assessment
c) This certificate will no be valid if the manufacturer makes any changes or modifications to the approved equipment, which have not been notified to, and agreed with RINA
d) RINA personnel are to be allowed to witness during the performances of activities, upon their request
e) The activities are to be carried out in compliance with the RINA Rules and/or other applicable Rules

f) Should the specified regulations or standards be amended during the validity of this certificate, the product is to be reapproved prior to it being placed on board vessels to which the amended regulations or standards apply. 


__________________________________________
Enrico Cabella
**** NOTICE: This is NOT an official certificate ****