Materials/Components
Control and instrumentation cables, fire retardant, low smoke, halogen free, with optional fire resistant, shielding and armoured constructions, for ships and offshore units.
Characteristic | Description |
| Cable type | TK SEA03, TK SEA04 |
| Rated Voltage | 150/250 V |
| Maximum conductor temperature | 90°C |
| Conductor | Bare/Tinned annealed Cu, IEC 60228 Cl.2, Cl.5 or Cl.6 |
| Fire resistant barrier | Mica tape over conductor (TK SEA04 only) |
| Insulation | XLPE |
| Core assembly | Pairs/Triads with fillers if required |
| Individual shield (optional) | Al/PET tape + tinned Cu drain wire |
| Collective shield (optional) | Al/PET tape + tinned Cu drain wire |
| Inner sheat (optional) | SHF1 |
| Armour (optional) | GSWB or plain/tinned Cu braid |
| Outer sheath | SHF1 or SHF2 |
| Marking | TECNIKABEL (TO) - ITALY - (week/year) - Type - n° x section mm² - Rated Voltage - Applicable Standard |
In accordance with IEC 60228; IEC 60092-350; IEC 60092-360; IEC 60092-376; IEC 60332-1-2; IEC 60332-3-22 Category A; IEC 60754-1; IEC 60754-2; IEC 61034-1; IEC 61034-2, RINA Rules for Ships; RINAMIL Rules; RINA Rules
for FSRU; RINAMIL for FREMM..
Additionally for TK SEA04: IEC 60331-2.
Type tested constructions include non-armoured SHF1 constructions, armoured SHF2 constructions, copper wire braid armoured constructions, galvanized steel wire braid armoured constructions, shielded constructions with individual and/or collective screens and fire resistant constructions incorporating mica tape.
ATTACHMENT TO
CERTIFICATE No. MED306326CS
Page 2 of 3
Technical Specifications:
TKSEA-03 Flame Retardant Rev.0 dated 18/06/2025;
TKSEA-03 Flame Retardant Armoured Rev.0 dated 18/06/2025;
TKSEA-04 Fire Resistant Rev.0 dated 18/06/2025;
TKSEA-04 Fire Resistant Armoured Rev.0 dated 18/06/2025;
ZZ62478-P Rev.2 dated 12/11/2024.
EMC performance ((in the marking "EMC"): transfer impedance: ≤ 25 mohm/m (0-100 MHz) acc. to IEC 62153-4-3
Drilling fluid resistance according to IEC 60092-360 Tab.9-10 with sheath SHF2 (in the marking "SHF2")
Type Test Reports:
Test Report No. 119 dated 09/06/2025;
Test Report No. 120 dated 09/06/2025.
Test Report N°92 rev.1 (23-26/03/2026)
Test Report N°85 rev.1 (23-26/03/2026)
Reference documents:
TAO-APP dated 25/07/2025
Offer 2026/16783accepted on 12/05/2026
The documents above-mentioned have been archived in the Leonardo Draw Plus portal under the project:
https://leodrawplus.rina.org/projects/82325/detail