MAC106523XGENGB- -  -  N- FIVA 1000 and FIVA 2000 -N- S- S- -17/04/2023- Prodotti Elettrici- - SN- N- Giuseppe Russo- N-  - 358,591Giuseppe RussoBbisProdotti ElettriciNumero Pratica,NumDich,Norma,NumBusta,Richiesta,Validità- MAC106523XG- N-358591
 
Form
  Prodotti Elettrici(TO)
MAC106523XG
Certification N. MAC106523XG - (ENG)
Certificate date 17/04/2023
Type Impianti di Automazione
Product Attuatore elettroidraulico per controllo valvole

Model or Denomin.
Items
FIVA 1000 and FIVA 2000
Applicant BOSCH REXROTH AG
Place of requester ZUM EISENGIESSER 1  %  97816 LOHR AM MAIN  % GERMANY
Tel. N.,Fax, Email 0049 9352 18 2729, 0049 9352 18 1293, ---
Standards Rules for the Classification of Ships - Part C - Machinery, Systems and fire protection - Ch.3, Sect.6, Tab.1.
Head Office Hamburg
Interrut.senza Dettaglio ENG
Vuoto Querysave
S
TYPE APPROVAL CERTIFICATE
No. MAC101518XG
This is to certify that the product below is found to be in compliance with the applicable requirement of the RINA type approval system.

Description Electro-hydraulic actuator for valves control
Type FIVA 1000 and FIVA 2000
Applicant BOSCH REXROTH AG
ZUM EISENGIESSER 1
97816 LOHR AM MAIN
GERMANY
Reference standards Rules for the Classification of Ships - Part C - Machinery, Systems and fire protection - Ch.3, Sect.6, Tab.1.
  

 
 
Issued in Hamburg on April 17, 2023.    
_________________________________
RINA Services S.p.A.
Giuseppe Russo
This certificate consists of this page and 1 enclosure
**** NOTICE: This is NOT an official certificate ****

TYPE APPROVAL CERTIFICATE
No. MAC101518XG
Enclosure - Page 1 of 1
FIVA 1000 and FIVA 2000
Product Description:
The FIVA 1000 and the FIVA 2000 are 5/3 way valves with integrated position feedback. The device controls the fuel injection valve (FI) and the valve activation (VA) on each cylinder of two stroke marine diesel engines.

Technical Data:


Material Body: EN GJS 400-15
Seal material: NBR (Perbunan)
Nominal Stroke: 15mm (FIVA 2000) and 16mm (FIVA 1000)
Operating Pressure: 300bar
Max. Operating Pressure: 350bar
Nominal Flow at 10 bar: 2000 l/min (FIVA 2000) and 1000 l/min (FIVA 1000)
Medium: Lubricating Oil OE HAT30 or equivalent
Purity Grade: ISO DIS 4406-/16/13 or NAS 1638 Class 7
Oil Temperature Range: +20°C up to 50°C
Electrical Supply: +24V DC
Command Signal Value: 6.2 to 18.7mA
LVDT Sensor: DM15/4
Pilot (FIVA 1000): R901184319-Vorsteurventil -22/STW0175-1X
Pilot (FIVA 2000): R901156092-Vorsteurventil -22/STW0280-12

Functioning:


Setpoints greater than 12 mA open the main spool, so that the pump pressure (P) is connected to the injection valve (FI) and the outlet valve (VA) to the tank. This configuration closes the outlet valve, and diesel fuel is forced out of the injection valve into the combustion chamber.
Setpoints less than 8.8 mA open the main spool so that the pump pressure (P) is connected to the outlet valve (VA) and the injection valve to the tank. This configuration opens the outlet valve, and the injection valve spool is pushed back into its initial position by the diesel fuel pressure.
In the range from 9.1 mA to 11.8 mA, FI and VA are connected to the tank at the same time.
The pilot has a fail safe position, i.e. if it opens the electrical energy the pilot spool goes to the position P to B and thus the main stage from P to VA. In the event of failure to reach the setpoint, the OBE (on bard electronics) switch the pilot spool into position P to B and thus the main stage into position P to VA. In the event of a drop in pressure, the weight of the main spool causes it to move slowly into position P to VA.

Application Fields:


The FIVA 1000 and the FIVA 2000 valve can be only installed on two strokes MAN ME-C Engines.

Documents:


Data sheet: - R901083669 (d); R901249427 (a)
Design Changes Protocol issued on 06.12.2011 and 8.12.2011
Drawing: - R901067851 (h); R901173564 (c); R901067850 (e); R901173563 (c);

Test reports:


Phoenix Testlab: - E090021E1 (21.04.09); U090021E1 2nd Version (20.07.09)
- ETR05-06/05_A01 (16.07.06); ETR09-05/02 (16.01.06); ETR 08-05/5 (17.10.05); ETR 10-05/07 (07.11.05)

Remarks:


- An alarm is to be activated in the IAS system in case of failure and the signal is to be visible in a manned position.
- The acceptance of the a.m. product on board ships and other units classed with RINA is subject to the satisfactory outcome of testing as per RINA Rules.
- This certificate replaces the previous one MAC101518XG.

Hamburg April 17, 2023
**** NOTICE: This is NOT an official certificate ****