TECHNICAL DATA
1, Product Description
150/250V shipboard communication and instrument cables having following rating:
Type Designation | Number of core or Pairs/Triples | Nominal Conductor
Cross-sectional Area [mm2] | Maximum rated
Conductor Temperature [0C] |
CKJPF, CKJPF80|90|86|96, CKJ86|96
CKJPJ, CKJPJ80|90|85|95, CKJ85|95
(/SC, /NC, /NSC) | 2
3(2+E)
4~37 |
0.5~2.5
| 90 |
CHJPF, CHJPF80|90|86|96, CHJ86|96
CHJPFP, CHJPFP80|90|86|96, CHJP86|96
CHJPJ, CHJPJ80|90|85|95, CHJ85|95
CHJPJP, CHJPJP80|90|85|95, CHJP85|95
(/SC, /NC, /NSC) | (1~48) ×2
(1~48) ×3 |
Note: +“Nominal Conductor Cross-sectional Area” is selected from the following series of core number:
0.5, 0.75, 1.0, 1.5, 2.5 mm2.
+“Number of Core” is selected from the following series of pair or triple number:
1, 2, 3, 4, 5, 7, 10, 12, 14, 16, 19, 24, 27, 30, 33, 37, 43, 48.
 | ATTACHMENT TO
CERTIFICATE No. MED461224WS
Page 2 of 4 |
+Conductor: Stranded bare or tinned annealed copper - Class 2 or 5
+Other properties’ suffix: CH: Shipboard communication cable
CK: Shipboard control cable
P: Individual screen
+Insulation: Cross-linked Polyethylene Insulation -XLPE(J)
+Inner Sheath: (Option):
Halogen Free Thermoplastic compound - SHF1 (PF)
Halogen Free Thermoset compound - SHF2 (PJ)
+Armor:
8: Copper wire braided
9: Steel wire braided
+Outer Sheath:
0: None
5: Halogen Free Thermoset Compound - SHF2
6: Halogen Free Thermoplastic Compound - SHF1
+Flammability Code:
SC: Halogen-free Low-smoke bunched flame retardant cable, comply withIEC 60332-1-2; IEC 60332-3-22 Cat.A;
IEC60754-1/2; IEC 61034-1/2,IEC 60684-2
NC/NSC: Halogen-free Low-smoke bunched flame retardant fire resistant cable, comply with IEC 60332-1-2;
IEC 60332-3-22 Cat.A; IEC60754-1/2; IEC 61034-1/2,IEC 60684-2;IEC 60331-1/2;IEC 60331-21.
 | ATTACHMENT TO
CERTIFICATE No. MED461224WS
Page 3 of 4 |
2, Application
The control and instrumentation cables are approved used for fixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces in marine and offshore filed.
3, Design Assessment The design assessment is based on SOLAS 74 Reg. II-2/7, IMO Res. IMO Res. MSC.36(63)-(1994 HSC Code) 7, IMO Res. MSC.97(73)-(2000 HSC Code) 7, IMO Res. MSC.98(73)-(FSS Code) 9, IMO Res. MSC.391(95)-(IGF Code) 11, IMO MSC.1/Circ.1242.
Cable installation in ships, as applicable, comply with IEC standards: IEC 60092-504:2016, IEC 60533:2015. IEC 60092-376:2017, IEC 60331-1:2018 or IEC 60331-2:2018.
4, Tests Carried Out
Test Report: “Shanghai Intelligent Service and Technology Co., Ltd” Report No.: TN22-2397E, TN22-2396E
and TN24-4789E. Filed by RINA with drawing No.:SHEL-20370.
Routine test Report and Narrative report signed by RINA Surveyor. Filed by RINA with drawing No.SHEL-20361.
5, Reference DocumentsTechnical drawings and manuals approved and filed by RINA listed on Approval letter No.: SHEL/2024/795/ZHITA and SHEL/2024/796/ZHITA. |