Reference documents
CSWD Series(0.8~70) Sewage treatment plants manufactured according to the Shanghai Shijiu Marine
Equipment CO., LTD technical specification and Drawings with RINA Approved No. SHMC-26801~26802 and SHMC-26805~26807.
Type approval test program prepared by manufacturer and reviewed with RINA No.SHMC-26803;SHMC-26797 and SHMC-26798
Influent/effluent samples Testing Report No.:HJ2100000219RR; HJ2100000220RR; HJ2100000223RR; HJ2100000224RR; HJ2100000244RR; HJ2100000246RR; HJ2100000273RR; HJ2100000286RR carried out by Ningbo Customs District Technology Center dated from 05/08/2021 to 22/08/2021.
Environmental Testing Reports carried out by China Waterborne Transport Research Insitute dated from 17/08/2021 to 26/08/2021 and from 29/10/2021 to 04/11/2021 as followings(No.): WT-2021-010(1)-DQ; WT-2021-010(2)-DQ.
Environmental Testing Reports carried out by Unilab(Shanghai) Testing Technology Co.,Ltd dated 30/08/2023 as followings: UL145420230627001
Technical characteristics
CSWD series(0.8~70) sewage treatment plants adopts a combination of oxidation degradation, microfiltration, electrocatalysis to treat sewage.
Model: CSWD Series | Capacity(m3/day) | Organic load(kg/day) |
CSWD-0.8 | 0.8 | 0.4 |
CSWD-1.5 | 1.5 | 0.75 |
CSWD-2.1 | 2.1 | 1.05 |
 | ATTACHMENT TO
CERTIFICATE No. MED447623WS
Page 2 of 5
|
Model: CSWD Series | Capacity(m3/day) | Organic load(kg/day) |
CSWD-2.8 | 2.8 | 1.4 |
CSWD-4.5 | 4.5 | 2.25 |
CSWD-5.5 | 5.5 | 2.75 |
CSWD-7 | 7 | 3.5 |
CSWD-10 | 10 | 5 |
CSWD-12 | 12 | 6 |
CSWD-15 | 15 | 7.5 |
CSWD-20 | 20 | 10 |
CSWD-25 | 25 | 12.5 |
CSWD-30 | 30 | 15 |
CSWD-35 | 35 | 17.5 |
CSWD-40 | 40 | 20 |
CSWD-45 | 45 | 22.5 |
CSWD-50 | 50 | 25 |
CSWD-60 | 60 | 30 |
CSWD-70 | 70 | 35 |
Discharge standard within the following limits:
Thermotolerant Coliforms (geometric mean) | Less than 100 cells/100ml |
5-day Biochemical Oxygen Demand(BOD5) | Less than 25 mg/l |
Chemical Oxygen Demand (COD) | Less than 125 mg/l |
Total Suspended Solids (TSS) | Less than 35mg/l |
PH value | Between 6.0 and 8.5 |
Total nitrogen | Less than 20 mg/l |
Total phosphorus | Less than 1.0 mg/l |
Field of application
Each sewage treatment plant is to be supplied with it's manual for installation, use and maintenance.
The installation on board is to be carried out in accordance with manufacturer's instructions.
A copy of this EC type-examination certificate shall be carried on board any ship, equipped with the above
discribed sewage treatment plant at all times.
Limitations and conditions of operation are imposed as follows: Inclination less than 22.5 degrees and
Viabration 2 to 13.2Hz with an amplitude of plus or minus 1mm and 13.2 to 80 Hz with an acceleration of plus
or minus 0.7g.
Marking of product
A plate or durable label shall be placed on the sewage treatment plant with at least the following information:
-Manufacturer's name or logo
-Model and serial number
-Hydraulic loading
 | ATTACHMENT TO
CERTIFICATE No. MED447623WS
Page 3 of 5 |
APPENDIX TO CERTIFICATE OF TYPE APPROVAL FOR SEWAGE TREATMENT PLANTS
Test results and details of tests conducted on samples from the sewage treatment plant in accordance with resolution MEPC.227(64), as amended:
Sewage treatment plant, Type: .........................................................CSWD-1.5&CSWD-7
Manufactured by: ..............................................................Shanghai Shijiu Marine Equipment Co.,Ltd
Organization conducting the test: ......................................Ningbo Customs District Technology Center
Designed hydraulic loading: ..................................................1.5 & 7................ .....m³/day
Designed organic loading: ................................................0.75 & 3.5................. kg/day BOD
Number of effluent samples tested: ..............................................40.........................
Number of influent samples tested: .................................................40......................
Total suspended solids influent quality: ............. ........................>500......................mg/l
Total nitrogen influent quality.....................................................>100.........mg/l as nitrogen
Total phosphorus influent quality............................................>20........mg/l as phosphorus
BOD5 without nitrification influent quality: .............................>500.............................mg/l
Maximum hydraulic loading: ..................................1.5 &7..................................... m³/day
Minimum hydraulic loading: .......................................1.5 &7................................. m³/day
Average hydraulic loading (Qi): ...............................1.5 &7.................................... m³/day
Effluent flow (Qe):...............................................1.5 &7 ........................................... m³/day
Dilution compensation factor (Qi/Qe):...................................1.....................................
Geometric mean of total suspended solids: ................................1.99/2.77.......................mg/l
Geometric mean of the thermotolerant coliform count:............<20....... coliforms/100 ml
Geometric mean of BOD5 without nitrification: .....................12.52/9.29............................ mg/l
Geometric mean of COD: ......................64.42/46.05.......................... mg/l
Geometric mean of total nitrogen ............................4.67/3.8.................................mg/l
Geometric mean of total phosphorus.........................0.09/0.04...............................mg/l
Maximum pH: .....................6.9/6.9...........................
Minimum pH: .....................6.3/6.4...........................
 | ATTACHMENT TO
CERTIFICATE No. MED447623WS
Page 4 of 5
|
Type of disinfectant used: ....................................electrolytic ........................................
If Chlorine - residual Chlorine:
Maximum:.......................................0.49/0.69.............................................. mg/l
Minimum: ........................................0.15/0.17.............................................. mg/l
Geometric Mean: .........................0.31/0.35................................................. mg/l
Was the sewage treatment plant tested with:
Fresh water flushing? ............................................................. Yes
Salt water flushing? ................................................................ Yes
Fresh and salt water flushing? ............................................... Yes
Grey water added? ......................................... Yes
Was the sewage treatment plant tested against the environmental conditions specified in section 5.9 of resolution MEPC.227(64):
Temperature? ........................................................................... Yes
Humidity?.................................................................................. Yes
Inclination? ................................................................................ Yes
Vibration? .................................................................................. Yes
Reliability of Electrical and Electronic Equipment? .................... Yes
Limitations and the conditions of operation are imposed:
Salinity ...............................................<=35g/L.................................................
Temperature ...........................................as per Part 3,MEPC.107(49)............................
Humidity ...............................................as per Part 3,MEPC.107(49)...................................
Inclination .....................................................as per Part 3,MEPC.107(49) ............................
Vibration .............................................................as per Part 3,MEPC.107(49) ...........................
Results of other parameters tested ................................/ .......................................