Product Description:
Fuel Gas Analyser is a system allowing real time analysis of fuel gas. In less than 30 seconds it is possible to know fuel gas calorific value and methane number together with full gas composition. System is scalable and can analyse multiple feed streams and be used to verify the LNG bunker delivery note.
Technical Data:
Analyser scope: | The FGA consists of the following main units:
• Analyser cabinet with analyser module
• Analyser controller
• Pump
• Manifolds with 8 solenoid valves
230/220VAC, 2-phase, 50/60 Hz power supply, 1000 W (while running)
Terminals for power and signal interfaces |
Operating conditions: | • + 5 to 60°C (gas)
• Inlet pres: 1-10 barg
• Outlet pres: up to 5 barg (15 barg as optional)
• IP65
• Ex hazardous rating:
II 2G Ex db eb [ia Ga] mb IIB T3 Gb
• 0-0.5 l/min gas flow
• 230V/24VDC
• Modbus TCP (ProfiBus/Net on request) |
Analyser performance:
| Values | Range | Accuracy |
| Methane | 0-100% | 0.5%Vol |
| Ethane | 0-20% | 0.5%Vol |
| Propane | 0-20% | 0.5%Vol |
| Iso-Butane | 0-5% | 0.2%Vol |
| N-Butane | 0-5% | 0.2%Vol |
| C5 total | 0-2% | 0.2%Vol |
| CO2 | 0-10% | 1.0 %Vol |
| Nitrogen | 0-100% | Balance |
| Calorific Value (GCV) (ISO 6976:2016) |
|
|
Methane Number (MN) (ISO
22302:2014) |
|
|
| Detection type | Response time |
| Detailed Analysis Calorific value | < 30 sec |
| Calorific Value - Change Detection | < 5 sec |
TYPE APPROVAL CERTIFICATE
No. ELE149326XP
Enclosure - Page 2 of 2
FUEL GAS ANALYSER
Reference Documents:
121-28786-1 - Test report - Test for marine type approval - Norsk analyse AS - FGA.pdf
DNV GL report Verification Tunable T1000 LNG Analyser, OGNL.204872B.pdf
FGA - Binder - 09.09.26b.pdf
FGA D212-05 Signal Exchange List.pdf
FGA-D120-03 Datasheet.pdf
FGA-D21-05 User Manual.pdf
FGA-D22-03 Installation Manual.pdf
FGA-D40-01 Utility Specifications.pdf
FGA-D44-05 Internal Test Procedure.pdf
FGA-D60-03 EX Certificates Fuel Gas Analyser.pdf
NA_FGA Analyser Module - DNV Type approval - TAA00002Y9_1.pdf
Application Fields:
• Engine optimisation
• Methane slip reduction
• LNG bunker verification
• LOC emission measurements
• Fuel Mixer (NH3 and H2)
• Power plants
Remarks:
This Type Approval certificate does not cover the gas sample lines as well as Ex-certification.
Application in hazardous area to be approved in each case according to the Rules and Ex-Certification/ Special Condition for Safe Use listed in valid Ex-certificate issued by a notified/recognised Certification Body.
Acceptance condition
The acceptance of the above mentioned product on board ships and other units classed with RINA is subject to the satisfactory outcome of testing as per RINA Rules.